Opening of the balancer

Before each intervention, the spring/drum (27) must be released
For that, turn the screw (9) counterclockwise.
There are two possibilities to verify it:
1)
About 4-6 mm protruding of the screw (9) (drawing H)
2)
Little movement of the drum (27), when turning it with the wire by handcraft.
Install the balancer on an horizontal and stable surface.
Remove all 4 screws (1), lift the cap (11) and pull the wire (28) completely off.
The inner diameter of the spring must be stranded on the shaft (drawing L).
Verify the wire: if it shows wears according to type B or C, replace it immediately
(drawing I).
Verify the function of all gears during operation: frictionless axial running and twisting of the screw (9).
Make sure that the spring (12) squeezes the safety device (13) clamped with the screw (14) in Position H1 > 8 mm
(drawing G).
If squeezing the screw (9) down to the bottom, the screw end operates on the inclined surface of the device (13) and make it
fall in the position H2 < 2,5 mm (drawing G).
The screw (14) must hold back the safety device (13) in such a way it can freely move. So the pressure between H1 and H2
will be changed without any friction and resistance.
Make sure that the wire (28) is perfectly hold through the lock (25) and that the fastening screw (26) does not protrude
(drawing M).