Please note!
Never release the balancer with a drafted wire and without screwed load (6)!
! The wire should resile and cause personal injury or material damages!
If the spiral spring breaks, the lowering of the load will be locked.
If the load capacity has been adjusted under the permitted minimum, the load should also be locked during lowering.
If operating under above conditions, the load has to be supported or a safety bracket, against falling, has to be installed.
It is strictly forbidden, also during maintenance, to access the spring/drum unit (27).
The spring/drum unit (27) will be delivered assembled.
In case of damages, the complete unit has to be replaced.
Drawing F
Anti fall guard:
Under normal conditions, the spring/drum (27) exercises a
torque on the gear (19). Whereby the end of the screw (9)
pushed upward locks the safety device (13).
(drawing F)
Drawing G
If the spring/drum (27) breaks, the spring (12)
squeezes the device (13) toward the washer
(D). Thereby the torque of the drum (27) is
locked and consequently the load lowering is
interrupted (drawing G1).