Descriptions of display-functions
A
Trend / tendency display
B
Wheather forecast symbols
C
Channel number
D
Outdoor temperature
E
Indoor temperature
F
Pressure bar chart
G
Pressure reading
H
Clock display
I
Day / month display
J
Low battery indicator main unit
K
Low battery indicator remote sensor
L
Indoor humidity
M
Clock alarm
N
Radio controlled clock
O
Day of the week
BATTERY INSTALLATION
Home Receiver:
Lift off the battery cover  at the back, install 2
pcs AA batteries according to the polarity indicated,
close the battery cover.
Remote Sensor:
Lift off the bracket stand, loose the 4 screws 
with a small screwdriver, insert 2 pcs AAA batteries
according to the polarity indicated. Replace the cover
and tighten the 4 screws.
SETTING UP THE WIRELESS THERMOMETER:
• For the first installation, always insert batteries
to the home unit and then the remote sensor.
Your new RF Thermometer is build with random
security code technology, the home unit will learn
the random code of the remote sensor and log in
as channel 1 (C).
English
A
B
C
D
E
F
G
H
I
• A registered channel will not accept any new sen-
sors. The registered channels will be erased when
the batteries of the remote sensor or the home
unit are removed.
• When replacing batteries for the remote sensor,
remember to clear the corresponding channel of
the home unit by removing the batteries or in this
way: Select the respective channel by pressing
the "CHANNEL" 1 button, hold the "CHANNEL"
1 button 3 seconds to clear the registration.
• When replacing batteries for the home receiver,
please remove batteries of all remote sensors and
re-install the batteries to the sensors according to
the desired channel sequence.
• Press the "Tx"  button on the back of remote
sensor to verify the RF reception, hold the button
3 sec to reset.
°C/°F SELECTION
By pushing "C/F" , enter the setting mode to
select C and F.
8
J
RADIO-CONTROLLED CLOCK
The unit will start synchronizing the clock after the
1st channel of the RF thermometer is registered.
At normal mode, hold " " 7 button 3 seconds for
force synchronization. The antenna icon " " (N) will
appear during synchronization, if the icon disappear
afterwards, radio time signal is not available at the
K
moment. Try other locations later. Place the unit
away from source of interference such as mobile
phones, appliances, TV etc. Antenna icon will appear
fix on screen if the radio time reception is suc-
L
cessful. The radio-controlled clock will have a daily
synchronization at 01:00 everyday. Maximum 4 more
attempts at one hour interval. Each reception cycle is
minimum 1.5 minutes and maximum 4 minutes.
SETTING UP THE BAROMETER
When power up, the pressure/ altitude display will
show "Auto" and "meter" for 60 seconds, it will
automatically estimate and display the current altitude
M
above sea level. Please compare the displayed alti-
N
tude value (in meters) against the exact altitude you
obtained from local authority. Enter your value if the
displayed value is not exactly correct. Press „+" 3 or
„–" 4 to enter the altitude value, press „HISTORY"
O
2 to confirm. The advanced micro-processor will tell
you what is the existing weather in your location. The-
re is no need to enter the existing weather to the unit.
SUNNY
SLIGHTLY CLOUDLY
Pressure Tendency (A):
Rising
CLOCK & CALENDAR SETTING
Hold "SET" 5 button for 3 seconds to enter clock
set. Using "+" 6, "-" 7" to adjust and "SET" 5 to
confirm, the following values can be set in sequence:
12/ 24 hr > C/F > Yr > Month > Date > Language
> Hour > Minutes > Time Zone (Switzerland „1") >
Confirm & Exit.
LANGUAGE
GE = German / En = English / FR = French /
IT = Italian / SP = Spanish
To offset the above again, please follow these steps:
1. Hold "PRESSURE/ ALTITUDE / +" 3 key 3
seconds
2. Select Meter or Feet by press "PRESSURE/ ALTI-
TUDE / +"3, press "HISTORY" 2 to confirm
3. Press "PRESSURE/ ALTITUDE / +" 3 and "-" 4
to enter the altitude value(-100 m to 2500 m)
4. Press "HISTORY" 2 to confirm & exit
To select mb/hPa and inHg, hold "-" 4 key 3 seconds
To view air pressure for the past 12 hours, press
"HISTORY" 2 to select and view. The respective
values can only be available after the barometer
recorded the pressure data in the past 12 hours.
The spectrum bar chart (F) indicates the pressure
changes (range from –8 to +8 hPa mb) of the past 1,
2, 3, 6 and 12 hour.
WEATHER FORECAST
The unit predicts weather condition of the next 12
– 24 hours based on the change of atmospheric pres-
sure. The coverage area is around 30 – 50 km. The
weather forecast is based on atmospheric pressure
change and is about 70-75% correct. As weather
conditions cannot be 100% correctly forecasted,
we cannot be responsible for any loss caused by an
incorrect forecast.
CLOUDLY
RAINY
Steady
Falling
ALARM SETTING
Hold "CLEAR/ AL"8 for 3 seconds. Press "+"6, "-"
7 to select AL 1 or AL 2 and press "CLEAR/ AL" 8
to confirm. Press "+" 6, "-" 7 to enter the desired
Hr/ Min values and press "CLEAR/ AL" 8 to confirm
setting.
To view alarm time 1 and 2, repeat press "CLEAR/
AL" 8 button at normal mode. Alarm time 1 or 2 will
display for 10 seconds and resume to normal clock
thereafter. To turn Alarm 1, 2 on and off, repeat press
"+" 6 button at normal mode.
The unit will provide Daily Alarm which last for 1 minu-
tes. At snooze mode, the alarm will repeat 10 minutes.