Start-up
Step switch material thickness / weld-
57
ing step
by setting the stepswitch, for approx.
2 seconds the material thickness alt.
welding step will be displayed in the
7-segment-display 47.
Symbol 230 V
58
lights up if 230 V is selected (applica-
ble for units with voltage changeover
switch)
Symbol 400 V
59
lights up if 400 V is selected.
60
Trigger Mode
to select 2-stroke, 4-stroke, spot weld-
ing or interval mode.
Turning knob wire feed
61
for adjustment of wire feed.
By activation of the turning knob, the
wire feed will be displayed as correc-
tion value in % on the 7-segment dis-
play 47, after setting the speed will be
displayed in m/min.
10.13