CUS400M Handbook
Fuse options
Blank
= Dual fused
E
= Single fuse in the live line
Signal, standby options
X2
= option board 2: 5V 2.0A standby supply, remote on/off (enable), dc good, ac fail, remote sense
X3
= option board 3: 12V 0.83A standby supply, remote on/off (enable), dc good, ac fail, remote sense
X5
= option board 5: 5V 2.0A standby supply, remote on/off (inhibit), dc good, ac fail, remote sense
X6
= option board 6: 12V 0.83A standby supply, remote on/off (inhibit), dc good, ac fail, remote sense
Leakage current options
S
= industrial leakage <3.5mA (60950-1 and 62368-1 only)
Blank
= standard leakage <250µA
R
= reduced leakage <150µA
T
= reduced leakage <50µA
Unit Product Code may be prefixed by K, SP followed by / or -
For units with non-safety related changes eg. Reduced OVP, current limit etc.
Unit product code is followed by "-NNNNL", where N is a string of numbers which identifies the unique
requirement. And L is a letter, starting with "A", which is incremented for any customer revision.
Example: CUS400M-24/FE-0001A
For non-standard units:
Prefix with "K". Follow by basic model type eg. CUS400M. Followed by "-NNNNL", where N is a string of
numbers which identifies the non-standard requirement. L is a letter, starting with "A", which is incremented
for any customer revision.
Example:
KCUS400M-24-0001A
Input Parameters
Parameter
Nominal input voltage
Input voltage range
Input frequency range
Maximum input current
** For operation at 440Hz, please contact Technical Sales.
60601-1
100 - 240Vac
90 - 264Vac
47 - 63Hz
5.75A rms
Page 15 of 22
60950-1 & 62368-1
100 - 240Vac
90 - 264Vac
47 - 63Hz**
5.75A rms
260519-02 Apr 2020