Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

OPERATING INSTRUCTIONS

14 Technical data

16
Teach mode starts,
Check vertical and horizontal alignment of the cabinet.
but one door or both
Ensure that the cabinet doors are not being obstructed in
doors do not open all
teach mode.
the way.
Check running track for obstacles.
Ensure that the cabinet doors have been correctly
suspended.
Perform soft reset as described in chapter "11.1 Soft reset".
Perform hard reset as described in chapter "11.2 Hard
reset".
One door or both
Check that all cables are properly connected and securely
doors not working
attached.
after successful
If LED lighting is connected, disconnect cable of LED
teach mode.
lighting from control unit and perform a hard reset as
described in chapter "11.2 Hard reset".
Once the teach mode has completed and the automatic
drive is operating correctly in Push To Go automatic mode,
connect cable of LED lighting to control unit.
Optionally connected
Check that all cables are properly connected and securely
LEDs not working.
attached.
With multiple LED lighting, test each connection
individually.
Mains supply
Stand by
Automatic mode
Safety type
Temperature range
Individual cabinet door weight
LED output
Minimum cabinet height
Permitted cabinet door weight
Travel distance per cabinet door max. 2,000 mm
Drive length
The type plate is attached to the control unit. The exact type designation and the
date of manufacture (month/year) of the automatic drive can be found on the type
plate.
100 - 240 V AC, 50/60 Hz
< 1.0 W
max. 25 W
For dry rooms only - IP 21
+10°C to +40°C
20 kg - 100 kg when using a TS1xxxxA control
unit
12 V DC, 0.8 A continuous (10W), 1.5 A
periodic duty
1.80 metres
20 kg to 100 kg per cabinet door
max. 4,000 mm