OPERATING INSTRUCTIONS
12 Maintenance and
cleaning
13 Troubleshooting
and fault remedying
Automatic cabinet door closing
If a suspended door cabinet is open, the open cabinet doors are closed
automatically after approx. 2 minutes.
Operation during and after a power failure
In the event of a power failure, the cabinet doors can be opened and closed by hand
at any time.
If the power failure occurs during a self-test, this is evaluated as "not successfully
completed" and an appropriate error is entered in the control unit.
This error entry results in the control unit being deactivated for safety reasons.
To restart the control unit, perform a hard reset as described in chapter "11.2 Hard
reset".
If the power failure occurs during the teach run in teach mode, the end position is
not correctly saved.
To restart, perform a soft reset as described in chapter "11.1 Soft reset".
11.6 Taking out of service
• Unplug the control unit from the power supply.
• The automatic drive is maintenance free. Maintenance and repair work or the
introduction of lubricants are not permitted.
WARNING
Risk of short circuits or fires due to improper cleaning!
> Never clean the automatic drive with liquids, damp cloths, cleaning
agents containing alcohol, solvents or thinners.
> Do not use high-pressure or steam cleaning equipment.
> Unplug the equipment from the mains before cleaning.
• If necessary, clean all surfaces of the automatic drive with a dry, soft cotton cloth,
applying gentle pressure.
In the event of damage or problems that cannot be remedied using the measures
described in this chapter, disconnect the automatic drive from the power supply and
contact the manufacturer (see last page for address).
• Unplug the equipment from the power supply before remedying faults.
• Use suitable, checked and stable climbing aids for overhead work.
Teach mode not
Check that all cables are properly connected and securely
starting.
attached.
Perform soft reset as described in chapter "11.1 Soft reset".
Perform hard reset as described in chapter "11.2 Hard
reset".
One of the cabinet
Check that all cables are properly connected and securely
doors stops in teach
attached.
mode.
Perform soft reset as described in chapter "11.1 Soft reset".
Perform hard reset as described in chapter "11.2 Hard
reset".
en
15