Start-up
Attention! Never operate the unit with a water pressure of more than 2.9 psi (0.2 bar)!
Attention! Never operate the unit without water or without a pump filter!
Note!
For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into
the casing.
B
This is how to connect the power supply:
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Check the correct seating of hoses and cover cap prior to starting up. Never operate the UVC clarifying unit without
water.
Switch on the pump and wait until the filter housing is filled with water. Check all connections for leaks.
Connect the power plug of the UVC clarifying unit, the blue control lamp is lit (B). In the event of overheating, the tem-
perature monitor switches the UVC clarifying unit off automatically, the UCF clarifying unit automatically switches on
again once it has cooled down.
Note: After a new installation, the unit only reaches its full biological cleaning effect after a few weeks. The full effect
on bacteria is only reached as from a water temperature of 50 °F (+ 10 °C).

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns.
Protective measures:
• Never operate the UVC lamp outside its housing.
• Never operate the UVC lamp in a housing that is defective.
Danger: Ultraviolet radiation.
Do not expose eyes to lamp rays.
Disconnect power before servicing or replacing lamp.
Replace lamp only with lamp rated 9 watts:
Warning: To reduce the risk of electric shock - Connect only to a circuit that is protected by a ground-fault
circuit interrupter (GFCI)
For indoor and outdoor household use
Attention! Breakable glass.
Possible consequences: Injury to your hands caused by cuts.
Protective measures: Handle the quartz glass and UVC lamp with care.