Assembly Instructions

Warning!
• Operate the product only with safety extra low voltage (SELV). Do not earth the
components.
• The power supply (not included in the scope of delivery, see accessories,
Chapter
14) must be set up outside of the wet area, in a separate room.
• Secure the electric connection with an earth leakage circuit breaker (RCD).
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
The system line (not included in scope of delivery, see Accessories,
connecting the power supply to the fittings must be installed in a conduit (to be
supplied by customer) and looped through.
Warning!
Operate this valve only in conjunction with the correct filter.
Failure to observe can lead to a damaged fitting.
Important!
Before installing, flush the pipes in compliance with DIN 1988.
Check the direction of flow.
a: Sensor
Installing the Electronic T-junction
Important!
The components of the electronic T-junction must be installed only when they are in
a dead condition.
Recommended system lines see Chapter 14., Accessories.
When using other cables for the system line, note the different colour coding. The
outer diameter must not exceed 7.5 mm.
9.1
Strip the shielding (b) off from the system lines (approx. 40 mm).
9.2
Fit the union nut (d) on the system line (c) up to the stop.
The cable cores are marked with numbers 1 through 4.
A: Union nut
B: FAR-Order-No. 84-032-12.468
FAR-Order-No. 84-032-12.534
FAR-Order-No. 84-032-12.563
FAR-Order-No. 84-032-12.720
9.3
Latch the cable cores (e) into the cable core guides (f) according to their colours.
6
Chapter
A
1
brown
2
white
3
blue
4
black
14) for
B
red
white
blue
black