5.
Application
A3000 open non-touch, electronically controlled urinal flushing valve, with concealed
activation via thermal ring sensor, with combined controller and solenoid valve for
concealed mounting, with facility for externally controlling options such as fitting
settings and communication via ECC function controller. Split-second adjustment of
flow duration.
Control functions:
– Optional temperature sensor with temperature measurement and protocol
saving every 60 seconds, during thermal disinfection every 10 seconds
– Time-controlled hygiene flushing, optionally with fixed interval or after a certain
defined time after last usage
Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning switch-off
6.
Technical Specifications
Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculation flow rate:
Flush flow rate:
Flush water volume:
Operating voltage:
Power consumption:
Type of protection:
7.
Dimensions
8.
Installation Example
A: Front view
B: Front view of wall niche
C: Side view
D: Engineering room view
1.0 bar
1–5 bar
10 bar
0.3 l/s
0.3–0.7 l/s
2-4 l adjustable
24 V DC
7 W
Electronic IP 68, solenoid valve IP 40
5