3.6 Electrical installation, pump
Check that the voltage stated on the identification plate is the same
as the battery voltage (12 or 24 V).
Consult the wiring diagrams on pages 42 and 43 when connecting
the pump. Extend the connector wires if required. Use good quality
wire connectors together with the right wiring pliers! Make sure that
all electrical connections remain dry under normal conditions in or-
der to prevent electrolysis and corrosion.
The minimum cross-section for the connecting cables is 2.5 mm
(AWG 14). The voltage drop between the battery and the pump
should not exceed 10% of the supply voltage. For a 12 Volt installa-
tion with a total cable length (positive and negative wiring added
together) of more than 19 m use cable with a cross-section of 4 mm
(or more than 50 ft: use AWG 12).
Connect the power supply as shown in the wiring diagram. See draw-
ing at page 26.
A main switch* and a fuse** must be incorporated in the positive ca-
ble.
Make sure the + (plus) and - (minus) connections are made prop-
erly!
Red is +, black is -.
*)
The switch must be rated for 15 Amps.
**)
Fuse:
10 Amps for 12 Volt system
7.5 Amps for 24 Volt system
The electric motor may become hot when used for a longer period
of time!
Make sure that electric wiring etc. does not get in contact with the
motor housing.
3.7 Electrical installation, level sensor and level gauge
The previously installed tank level sensor (Art. code: SENSOR320)
measures the liquid level. The sensor can be used in combination
with a Vetus level meter.
Note: Not included in the delivery.
Order information:
Art. code:
Description
WATER12B
Level meter (drinking water) with black
dial
WATER24B
WATER12W
Level meter (drinking water) with
cream dial
WATER24W
WATER12WL
Level meter (drinking water) with white
dial
WATER24WL
• Connect the sensor to the tank level meter as shown in the wiring
diagrams, see page 27.
See 'Use' before making use of the tank.
8
050407.01
W
arning
12 V
24 V
12 V
24 V
12 V
24 V
4 Technical Data
Drinking water tank system
DWSC :
Type
DWSC
Capacity litres *) :
Imp.gal. *) :
US gal. *) :
Weight
kg *) :
2
lbs *) :
Max. pressure
: 30kPa (0.3 bar, 4 psi)
Material:
: polyethylene MDPE (Medium Density Poly-
2
.
Material meets the KTW standard.(http://www.dvgw.de/465.html)
Tank wall thickness
: 6.35mm ± 1.3mm (1/4" ± 3/64")
*) The values shown are the nominal values for the capacity and
weight. Slight differences are possible.
Dimensions of fittings:
for drinking water pipe : ø 12mm (
for venting
for filler hose
Pump
Type
: Self-priming diaphragm pump
Number of valves
: 3
Capacity
: 13.2 l/min (2.9 Imp. gal/min, 3.5 US gal/min)
Max. pressure
: 3.1 bar (45 psi)
Maximum riser height : 1.8 m (6 ft)
Material,
Pump head
: Polypropylene, Viton®, Stainless steel
Diaphragm
: Santoprene®
Valves
: Viton®, Polypropylene
Filter, Type
: In-line
Mesh size
Pressure switch, Settings
Switch-on pressure : 1.9 bar (28 psi)
Switch-off pressure : 3.1 bar (45 psi)
Electric motor
Type
Voltage
Current, maximum:
Level sensor
Power supply
Output
DWSC Drinking water tank systems 42, 61, 88 and 120 litres
04212
06112
08812
04224
06124
08824
42
61
88
9.2
13.4
19.4
11.1
16.1
23.2
8.7
10.1
12.3
19.2
22.3
27.1
ethylene) foodstuffs quality, colour: green
1
/
")
2
: ø 16mm (
5
/
")
8
: ø 38mm (1
1
/
")
2
: 50 Mesh
: Permanent magnet direct current motor
:
12 Volt
24 Volts
:
7 A
4 A
: 12 or 24 Volts
: Analogue, suitable for 1 Vetus tank level
meter
12012
12024
120
26.4
31.7
13.5
29.8