2nd LED is green FIX if a Central is linked
During this menu the RF is always ON to be able to pair a central with the
thermostatic head. For this follow the instruction of the Central unit and
put the Central first in RF pairing mode (before the thermostatic head)
Push OK to go back to SETUP 1 selection menu.
The thermostatic head is now ready to work with the Central Unit.
The default working mode will be the mode imposed by the Central Unit.
2.4 ITCS
ITCS Intelligent Temperature Control System requires a central unit.
This function will activate your installation in advance (2 hours maximum)
to assure the desired temperature at the hour programmed following your
weekly program.
This automatic control system works in the following way:
When you start your thermostatic head for the first time, it will measure
the time taken by your heater to reach the set temperature. The thermo-
static head will re-measure this time at each program change to com-
pensate external temperature change & influence. You can now program
your thermostatic head on the central without the need to adjust the tem-
perature in advance because it does automatically this for you
By default, this function is ACTIVATED.
In the set-up1 menu select the 3rd LED,
3rd LED is red FIX if ITCS is OFF
3rd LED is green FIX if ITCS is ON
Switch from OFF to ON by moving left and right
Push OK to go back to SETUP 1 selection menu.
2.5 Calibration of the internal probe
If the temperature regulation made by My Head seem not appropriate
(in case of big room or hide radiator) the internal probe calibration could
be needed.
Cod. 1910000000260 - nv00
The calibration must be done after 1 day working with the same
setting temperature in accordance with the following description:
Put a thermometer in the room at 1.5m distance from the heater and
check the real temperature in the room after 1 hour.
By default, there is no offset.
For the regulation, the thermostatic add the difference between the set-
point and the measurement made on the internal probe.
Example:
Set
point=21°C,
set=21°C-19°C=+2°C
In the set-up1 menu, 4th LED
No LED => no offset
Move left and right to decrease/increase offset value
with 0.5°C steps. Possible values [-5;5]
-5° offset
-4,5° offset
-2,5° offset
-2° offset
0,5° offset
1° offset
3° offset
3,5° offset
Push OK to validate and go back to SETUP I selection menu
2.6 Open window detection
Conditions of open window detection:
The thermostatic head detects an "Open window" if the room tempera-
ture decreases by 5°C or more during a 30 minutes period (or less).
In this case, the thermostatic head follows 7.0°C setting.
The function remains active until the room temperature increases or until
any key is pressed.
- 13 -
English
Measured
temperature=19°C,
-4° offset
-3,5° offset
-3° offset
-1,5° offset
-1° offset
-0,5° offset
1,5° offset
2° offset
2,5° offset
4° offset
4,5° offset
5° offset
Off-