User manual - Thermostatic head My Head
IMPORTANT!
-
This product should be installed preferably by a qualified pro-
fessional. Subject to observation of the above terms, the man-
ufacturer shall assume the liability for the equipment as provid-
ed by legal stipulations.
-
All instructions in this Installation & Operation manual should
be observed when working with the controller. Failures due to
improper installation, improper use or poor maintenance are
voiding manufacturer liability.
-
Any attempt to repair voids the responsibility and the obliga-
tion to guarantee and replacement from the manufacturer.
Application
-
The CORDIVARI MY HEAD is developed to control and manage
many types of Hydraulic Heaters: M30 x 1.5, M28 x 1.5, M24 x 1.5
-
The controllers have been designed for use in residential rooms,
office spaces and industrial facilities.
Verify that the installation complies with existing regulations before oper-
ation to ensure proper use of the installation.
1. Presentation
LED 3
LED 2
LED 1
LED 7 (Status/Mode LED)
Electronic programmable thermostatic head, specially designed to con-
trol different types of hydraulic heaters.
It will be your best partner to optimize your energy consumption and in-
crease your comfort.
-
Modern design.
-
Stand alone or Wireless Bidirectional communication 868.3 MHz
with Central Unit compatibility
-
Adaptive PID regulation for better comfort and energy saving
-
Temperature sensor calibration
-
Open window function
-
Ant grip
-
EEPROM nonvolatile memory.
-
2 AA batteries (LR6)
-
3 types of adapters to be mounted on hydraulic heaters:
∙
M30 x 1.5
∙
M28 x 1.5
∙
M24 x 1.5
In combination with the central unit
Cod. 1910000000260 - nv00
LED 4
LED 5
LED 6
OK Button
Rotary switch
-
"Easy program creation" function.
-
Weekly programmable by step of 15min.
-
Temporary override function.
-
Anti-freeze function
-
ITCS Intelligent Temperature Control System
2. First Installation
2.1 Batteries installation
-
Open the battery cover and insert the 2 AA Alkaline supplied batter-
ies (or remove the small protection sticker if the batteries are already
installed in the compartment).
-
Close the battery cover.
-
All parameters of My Head are available in two different menus.
SetUp1 menu
3
4
2
5
1
Setup2 menu
3
2
1
To access to Set Up1 menu,
•
Push one time OK to wake up the thermostatic head
•
Push 10s on OK key.
All LEDs are green during 1s
1st LED blinks green and user is allowed to choose
setup menu number by turning the rotary switch.
Push the OK button to validate the Setup menu
from 1 to 6
My Head can automatically leave SetUp1 menu in case of no user
action for 30 seconds.
To access to Set Up2 menu,
•
Push one time OK to wake up the thermostatic head
•
Push 20s on OK key
- 11 -
English
6
1. Motor Learning
2. RF Pairing
3. ITCS
4. Calibration
5. Open Window
6. Exit SetUp1
4
1. Brightness
2. Antigrip
3. Bypass
4. Exit SetUp2