Red-lighted LED indicating:
•
Lack of water alarm ON, for
booster application
6
or
•
High level alarm ON, for sew-
age application.
Red-lighted LED indicating Tem-
7
perature °C, if selected
Red-lighted LED indicating head
8
(water column) in m, if selected
Steady green-lighted LED, indicating
9
the power is on
Red-lighted LED indicating pressure
10
in bar, if selected
Locking/unlocking the user inter-
5.2.1
face
The buttons (4) are enabled in AUTOMATIC or
MANUAL mode and allow the user to view the
operation and alarms log (see section 5.4.2) or to
access the menus and edit the operating parame-
ters (see section 5.4.3).
Start-up and programming
5.3
NOTICE:
•
If supplied individually, THE DEFAULT
SOFTWARE IS:
-
SEWAGE (SE) for Q-SMART10../D, Q-
SMART20../D, see section
5.4.3 tab. 2
-
PRESSURISATION
SMART10../B, Q-SMART20, see sec-
tion
3.2
and
5.4.3 tab. 3.
Edit the values according to the type of elec-
tric pump and system, see section
refer to figures
11
to 64.
•
When the control panel is already connect-
ed to an electric pump or a booster set, the
same has been programmed based on the
characteristics of the electric pump, and the
default values may change. Edit the function
values of the system.
•
Incorrect configuration can damage the
electric pump and/or the system.
Refer to figures
1
and
2
1.
Check that all the mechanical, electrical and
hydraulic connections have been made. See
Mechanical installation
installation
section 4.3.
2.
Turn on the power at the main switch (1) fig-
ure 7 and the control panel starts up.
3.
The control panel performs an internal hard-
ware Auto-test and the LED (9) turns on. It is
possible to enter the CONFIGURATION
MENU to set the proper application (refer to
figures
11
to 64).
NOTICE:
3.2
and
(bS)
for
Q-
5.4.4
and
for the user interface.
section 4.2,
Electrical
•
Start-up mode after a shutdown is always
AUTOMATIC, and cannot be changed.
•
In automatic mode, the electric pump runs if
the pressure, level or temperature of the
system is below the value selected. If nec-
essary, press (4) to set MANUAL mode and
the electric pump turns off if running.
The parameters in the PARAMETER menu can
be edited ONLY in STANDBY (StY) mode. Press
(4) to switch between AUTOMATIC or MANUAL and
STANDBY (StY) mode; the LEDs (5) and (2) are off.
See section
5.4.4
for the proper procedure.
Programming
5.4
The control panel has three menus that can be
accessed with a combination of keys:
•
QUICK CONFIGURATION (see section 5.4.3)
•
ALARMS LOG (see section 5.4.2).
•
PARAMETERS (see section 5.4.4).
Texts shown on the display
5.4.1
Sim
Description
Operation Manual mode: pump is
MAn
stopped
Aut
Operation Automatic mode.
StY
Standby mode: Programming is enabled
cnf
Software selection (sE or bS)
The Q-SMART control panel is set in
SE
SEWAGE mode.
Q-SMART control panel is set in Pres-
bS
surisation BOOSTER mode.
c
Configuration parameter
t
Timing parameter
r
Adjustment parameter menu
h
Hour and Data value
Shown on display when the analogue
---
sensor is not used. The digital sensor is
used.
When the analogue sensor is not used
run
(no feedback), the pump is running
A
Alarm log
tSt
Auto-test running
Q-SMART control panel is disabled by
the external command switch connect-
OFF
ed to the D IN PROGR (figure 9)
The status of the alarm in the alarm log.
On
The status of the alarm in the alarm log.
P1
Pump 1 runs
P2
Pump 2 runs
Alarm log
5.4.2
It is possible to view information concerning any
alarms in either MANUAL or AUTOMATIC mode.
The menu is read-only and displays the last 20
alarms that have occurred.
Refer to figures
1
and 2.
en - Original instructions
39