LEGRAND Wattstopper LMDM-101 Instructions D'installation
LEGRAND Wattstopper LMDM-101 Instructions D'installation

LEGRAND Wattstopper LMDM-101 Instructions D'installation

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

No: 23493 – 08/16 rev. 1
Catalog Numbers • Les Numéros de Catalogue • Los Números de Catálogo: LMDM-101
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
Models ending in -U are BAA and TAA compliant (Product produced in the U.S.)
This unit is pre-set for Plug n' Go™ operation,
adjustment is optional.
For full operational details, adjustment and more
features of the product, see the DLM System Installation
Guide provided with Wattstopper room controllers, and
also available at www.legrand.us/wattstopper.
Installation shall be in accordance with all applicable
regulations, local and NEC codes. Wire connections
shall be rated suitable for the wire size (lead and building
wiring) employed.
For Class 2 DLM devices and device wiring: To be
connected to a Class 2 power source only. Do not
reclassify and install as Class 1, or Power and Lighting
Wiring.
Do not apply cleaning solvent directly onto unit. Apply
cleaning solvent onto a cloth, then wipe the unit to clean it..
MOUNTING THE SWITCH
WARNING: Do not install to cover a junction box having Class 1, 3 or
Power and Lighting Circuits.
The illustrations here show examples of free-topology wiring. The LMDM communicate to all other Digital Lighting Management devices
connected to the low voltage DLM Local Network, regardless of their position on the DLM Local Network.
LMDM-101
LMSW-105
Occupancy Sensor
Dimming Switch
Scene Switch
LMDM-101
Dimming Switch
LMRJ Cables
CAUTION: TO CONNECT A COMPUTER TO THE DLM LOCAL NETWORK USE THE LMCI-100. NEVER CONNECT THE DLM
LOCAL NETWORK TO AN ETHERNET PORT – IT MAY DAMAGE COMPUTERS AND OTHER CONNECTED EQUIPMENT.
Line Voltage
Class 2 0-10 Volt Control Wiring
LMRC-212
Line Voltage
Dimming
0-10 Volt
Ballast
Room
Controller
J-Box
0-10 Volt
Ballast
Wattstopper
Digital Lighting Management Low Voltage Dimming Wall Switch (v3)
Gestion numérique de l'éclairage Interrupteur mural basse tension à gradation (v3)
Regulador de pared de bajo voltaje DLM (v3)
Quick Start Guide • Guide de démarrage rapide • Guía de inicio rápido
Voltage ................................................................................... 24VDC
Current Consumption ..................................................................5mA
Power Supply ...................................... Wattstopper Room Controller
Connection to the DLM Local Network ......................... 2 RJ-45 ports
DLM Local Network characteristics when using LMRC-11x/2xx room
controllers:
Low voltage power provided over Cat 5e cable (LMRJ);
max current 800mA. Supports up to 64 load addresses,
48 communicating devices including up to 4 LMRC-10x
series and/or LMPL-101 controllers.
Free topology up to 1,000' max.
Environment ...................................................... For Indoor Use Only
Operating Temperature ......................32° to 131°F (0° to 55°C)
Storage Temperature ........................23° to 176°F (-5° to 80°C)
Relative Humidity ............................5 to 95% (non condensing)
Patent Pending
Blue load
status LED
LEDs
show
light
level
setting
Rocker Panel
When all loads bound to the dimmer are OFF, the Blue load
status LED is dim. A single light level LED is lit to show the last
light level.
When any load bound to the dimmer is ON the load status
LED is bright. The number of illuminated light level LEDs
indicates the highest light level on any of those loads.
CONNECTIVITY
Daylighting
Sensor
®
SPECIFICATIONS
BUTTONS AND INDICATORS
Tap when load OFF: Turn ON to last level
Tap when load ON: Go to full bright
Press & Hold: Ramp Up
Configuration Button
(behind switch plate)
Tap: Fade to OFF
Press & Hold: Ramp Down
Red LED
Corner Mount
Occupancy
Sensor
J Box
LMRC-21x
Room
Controller
To
Load
To 0-10V
Dimming Ballast
DLM Local Network
(low voltage, Class 2)
LMRJ cables
Ceiling Mount
Occupancy
Switch/
Sensor
Dimmer

Publicité

Table des Matières
loading

Sommaire des Matières pour LEGRAND Wattstopper LMDM-101

  • Page 1 Power Supply ........Wattstopper Room Controller Guide provided with Wattstopper room controllers, and Connection to the DLM Local Network ......2 RJ-45 ports also available at www.legrand.us/wattstopper. DLM Local Network characteristics when using LMRC-11x/2xx room controllers: Installation shall be in accordance with all applicable Low voltage power provided over Cat 5e cable (LMRJ);...
  • Page 2 PLUG N’ GO OPERATION (PNG) All loads are automatically bound to the Line Voltage LMRC-213 LMDM-101. LMDM-101 LMDM-101 The rocker paddle on the LMDM-101 Loads controls all loads on the DLM Local 0-10 Volt Line Ballast Network. Tap the top of the rocker to Voltage 0-10 Volt turn ON all loads to the last light level.
  • Page 3: Spécifications

    Alimentation électrique ....Wattstopper contrôleur de pièce fourni avec les Wattstopper contrôleurs de pièce et aussi disponible au Connexion au réseau local DLM ........2 ports RJ-45 www.legrand.us/wattstopper. Caractéristiques du réseau local DLM pendant l'utilisation des contrôleurs LMRC-11x/2xx: L'installation doit être effectuée conformément à tous les règlements ainsi La basse tension est générée par le câble Cat 5e (LMRJ);...
  • Page 4: Connectivité

    CONNECTIVITÉ Les illustrations montrent des exemples de câblage de topologie libre. Les LMDM communiquent avec tous les autres dispositifs de gestion numérique de l'éclairage connectés au réseau local DLM basse tension, peu importe leur position dans le réseau local DLM. LMDM-101 LMSW-105 Détecteur de...
  • Page 5: Dépannage

    Étape 2 Sélection d'une charge 1. Pour faire le tour des charges connectées au réseau local DLM, appuyer et relâcher rapidement le bouton de configuration. La première pression du bouton éteint la charge 1 et allume la charge 2. La pression suivante éteint la charge 2 et allume la charge 3, et ainsi de suite.
  • Page 6 Suministro de energía ..Controlador de habitación Wattstopper proporciona con los controladores de habitación Wattstopper; también Conexión a la red local DLM ........2 puertos RJ-45 está disponible en www.legrand.us/wattstopper. Características de red local DLM al usar controladores de habitación LMRC-11x/2xx : La instalación debe realizarse conforme con todas las...
  • Page 7 FUNCIONAMIENTO DE PLUG N’ GO (PNG) Todas las cargas se vinculan Voltaje de línea LMRC-213 automáticamente al LMDM-101. LMDM-101 LMDM-101 El interruptor oscilante LMDM-101 Cargas controla todas las cargas de la red Balasto de Line 0 a 10 voltios local DLM. Toque la parte superior del Voltage Balasto de interruptor para activar todas las cargas...
  • Page 8: Solución De Problemas

    No. 23493 – 08/16 rev. 1 © Copyright 2016 Legrand All Rights Reserved. 800.879.8585 © Copyright 2016 Tous droits réservés Legrand. www.legrand.us/wattstopper © Copyright 2016 Legrand Todos los derechos reservados.

Table des Matières