4.u - ADVICES FOR CORRECT USE
•DO NOT bring cloths soaked with Alcohol, Acetone, Ammonia,
Bleach or Solvents into the proximity of the appliance.
•DO NOT use any kind of SPRAY near the gas detector.
• DO NOT carry out an operational test on the gas detector by
releasing gas directly from the gas pipe, lighters or lighter refill
cans.
•Cooking vapours and pollutant dusts can affect the
performance of the sensor over time.
•DO NOT ATTEMP TO OPEN THE CABINET: danger of electric
shock and malfunctions.
• On a periodic basis, check that the vents on the front panel of
the detector, which channel air to the sensor, are not
obstructed by dust or grease, etc.
•To clean this device make use of a lightly wet tissue.

INSTALLATION INSTRUCTIONS

surface mounted
OVERALL DIMENSIONS
82
120
1.i - INSTALLATION OPERATIONS
CURRENTLY NATIONAL STANDARDS ENFORCEABLE IN THE INSTALLATION
COUNTRY COVERING THE INSTALLATION AND USE OF GAS POWERED
EQUIPMENT ARE TO BE RESPECTED, AS ARE STANDARDS COVERING SMOKE
DISPERSION AND VENTILATION OF ENCLOSED AREAS, EVEN THOUGH GAS
DETECTION EQUIPMENT IS INSTALLED.
max 30 cm
Natural gas detector
LPG detector
max 30 cm
Install Natural Gas detector max. 30 cm from ceiling .
Install LPG detector
Install detectors from 1 to 4 m from gas appliances.
Do not install the detectors outdoors or in places exposed to atmospheric agents.
Do not install the detectors near: sink, air vents, HVAC appliances or windows;
semi flush mounted
furthermore, the detectors must not be installed in enclosed spaces, such as
(with optional support may
behind a curtain or inside a closet.
be purchased separately)
Note: in residential units with
several floors, communicating with
each other, additional gas
detectors must be installed.
Fig. 8
40
27,5
Example of installation
min. 1 m
max. 4 m
min. 1 m
max. 4 m
max. 30 cm from floor
.
Solenoid valve
EN
Fig. 7
13