G
AERASGARD
®
TECHNICAL DATA
Pressure dependence:
Long-term stability:
Gas exchange:
Ambient temperature:
Response time:
Electrical connection:
Housing:
Housing dimensions:
Cable connection:
Protective tube:
Process connection:
Protection class:
Protection type:
Standards:
Optional:
AERASGARD
®
ACO
- SD
2
®
AERASGARD
ATM - CO
2
AERASGARD
®
2
®
AERASGARD
2
®
AERASGARD
®
AERASGARD
Type ⁄ WG02
- SD
2
ACO2-SD-U
ATM - CO
- SD
2
ATM-CO2-SD-U
ACO
-W
2
ACO2-W (without display)
ACO2-W-DISPL AY
ALQ - CO
-W
2
ALQ-CO2-W
ALQ-CO2-W-DISPL AY
AFTM - CO
-W
2
AF TM-CO2-W
AF TM-CO2-W-DISPL AY
AFTM - LQ - CO
-W
2
AF TM-LQ-CO2-W
AF TM-LQ-CO2-W DISPLAY
Outputs:
Equipment:
Optional:
Note:
ACCESSORIES
SF-M
WS-03
- W ⁄ ALQ - CO
- W ⁄ AFTM - CO
2
2
± 0.13 % ⁄ mm Hg
< 2 % in 15 years
by diffusion
< 2 minutes
2
0.14 - 1.5 mm
, via screw terminals
plastic, UV-stabilised, material polyamide, 30 % glass-globe reinforced,
with quick-locking screws (slotted ⁄ Phillips head combination),
colour traffic white (similar to RAL 9016),,housing cover for display is transparent!
126 x 90 x 50 mm (Tyr 2)
cable gland, plastic
(M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
stainless steel V2A (1.4301), Ø 16 mm, NL = 55 mm
by screws
III (according to EN 60 730)
IP 65 (according to EN 60 529)
CE conformity, electromagnetic compatibility according to EN 61 326, EMC Directive 2014 ⁄ 30 ⁄ EU
three-line display with illumination, cutout approx. 70 x 40 mm (W x H),
for displaying actual humidity, actual temperature, air quality and / or the actual CO
On-wall CO
2
- SD
On-wall temperature and CO
2
On-wall air quality (VOC) and CO
2
for humidity, temperature and CO
Multifunctional on-wall sensor
2
for humidity, temperature, CO
Measuring Range
Humidity
Temperature
-
-
-
-35...+80 °C
-
-
-
-
-
-
-
-
0...100 % r.H.
-35...+80 °C
0...100 % r.H.
-35...+80 °C
0...100 % r.H.
-35...+80 °C
0...100 % r.H.
-35...+80 °C
0 -10 V or 4...20 mA (selectable via DIP switches, selected variant applies for all outputs) -
Standard on-wall sensor ATM - CO
W = changeover contact - Standard on-wall sensor ATM - CO
Cable connection with M12 connector according to DIN EN 61076-2-101 (on request)
This unit must not be used as safety-relevant device!
Metal sinter filter, Ø 16 mm, L = 32 mm, exchangeable
stainless steel V4A (1.4404)
Weather and sun protection hood, 200 x 180 x 150 mm,
stainless steel V2A (1.4301)
- W ⁄ ATM - CO
2
2
sensor, Standard
2
sensor, Premium
2
content, Deluxe
2
content and air quality (VOC), Deluxe
2
CO
VOC
2
(switchable)
0...2000 ⁄ 5000 ppm
-
(switchable)
-
(switchable)
0...2000 ⁄ 5000 ppm
-
0...2000 ⁄ 5000 ppm
-
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
(switchable)
0...2000 ⁄ 5000 ppm
-
0...2000 ⁄ 5000 ppm
-
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
- SD with fixed output 0 -10 V!
2
11
- SD ⁄ ACO
- SD
2
2
content
2
Equipment
Item No.
Display
(Baldur 2)
-
1501- 7110-1001- 200
-
1501- 7112-1001- 200
W
see ACO
-W ⁄ ACO
2
W
■
15 01-7110- 7371- 200
W
1501-7111- 7301- 200
W
■
1501- 7111- 7371-200
W
1501- 7116- 7301- 200
W
■
1501- 7116- 7371- 200
W
1501- 7118- 7301- 200
W
■
1501- 7118- 7371- 200
- SD without changeover contact !
2
7000- 0050-2200- 100
7100- 0040- 6000- 000
Rev. 2020 - V24
(continued)
-SD
2