S+S Regeltechnik THERMASGARD ATM 2 Notice D'instruction

S+S Regeltechnik THERMASGARD ATM 2 Notice D'instruction

Masquer les pouces Voir aussi pour THERMASGARD ATM 2:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6002-7100-2011-000 27100-2017 V101 12 ⁄ 2016
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Außentemperatur ⁄ Feuchtraumtemperatur-
messumformer, kalibrierfähig,
mit Mehrbereichsumschaltung und aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Outside temperature ⁄ wet room temperature
measuring transducers, calibratable,
with multi-range switching and active output
F
Notice d'instruction
Sonde de température extérieure ⁄ de locaux humides
avec convertisseur, étalonnable,
avec commutation multi-gamme et sortie active
r
Руководство по монтажу и обслуживанию
Преобразователь температуры измерительный наружный ⁄
для помещений с повышенной влажностью, калибруемый,
с переключением между несколькими диапазонами
и активным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ATM 2
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
ATM 2
ATM 2
mit Display
with display
avec écran
с дисплеем
ATM 2
mit ⁄ with ⁄ avec ⁄ с
SS 02

Publicité

Table des Matières
loading

Sommaire des Matières pour S+S Regeltechnik THERMASGARD ATM 2

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Page 2 D G F r ATM 2 THERMASGARD ®  ATM 2 Maßzeichnung Dimensional drawing Plan coté Габаритный чертеж mit Display with display avec écran с дисплеем M16x1.5 M16x1.5 ø 6 ø 6 M16x1.5 M16x1.5 M16x1.5 ohne Display without display ø 11 ø...
  • Page 3: Technische Daten

    ® THERMASGARD ATM 2 Rev. 2017 - V12 DE Kalibrierfähiger Außentemperaturmessumformer THERMASGARD ® ATM 2 mit acht umschaltbaren Messbereichen, internem oder externem Sensor, stetigem Ausgang, mit Gehäuse aus schlagzähem Kunststoff und Schnellverschlussschrauben, wahlweise mit ⁄ ohne Display. Er dient zur Erfassung der Außentemperatur, der Temperatur im Feuchtraumbereich, z.
  • Page 4 Messumformer, kalibrierfähig, mit aktivem Ausgang Bürdendiagramm TEMPERATURBEREICHE: Bürdendiagramm Bei der Auswahl der Messumformerbereiche ist 4...20 mA darauf zu achten, dass die höchstzulässige Temperatur des Fühlers ⁄ Gehäuses nicht über schritten wird ! Umgebungstemperatur für den Messumformer: – 30 ...+ 70 °C zulässiger Bürdenwiderstand = siehe Bürdendiagramm Bereich...
  • Page 5: Sicherheitsvorschriften

    Montage und Installation Die Geräte sind im spannungslosen Zustand anzuschließen. Der Anschluss ANSCHLUSSBEDINGUNGEN der Geräte darf nur an Sicherheitskleinspannung erfolgen. Folgeschäden, Ausgang: 0 -10 V welche durch Fehler an diesem Gerät entstehen, sind von der Gewähr- Die Ausgangsspannung folgt linear den am Eingang anliegenden Tempera- leistung und Haftung ausgeschlossen.
  • Page 6: Technical Data

    ® THERMASGARD ATM 2 Rev. 2017 - V12 GB Calibratable outside temperature measuring transducer THERMASGARD ® ATM 2 with eight switchable measuring ranges, internal or remote sensor, continuous output, terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws, with or without optional display.
  • Page 7: Temperature Ranges

    Measuring transducers, calibrateable, with active output Load resistance diagram TEMPERATURE RANGES: Load resistance diagram When selecting measuring transducer ranges, 4...20 mA it is necessary to ensure that the maximum temperatures permissible for sensor ⁄ enclosure are not exceeded ! Ambient temperature for measuring transducers: –...
  • Page 8: Safety Regulations

    Mounting and Installation Devices are to be connected under dead-voltage condition. Devices must CONNECTING CONDITIONS only be connected to safety extra-low voltage. Consequential damages Output: 0 - 10 V caused by a fault in this device are excluded from warranty or liability. The output voltage follows linear to the temperature signal applied at Installation of these devices must only be realized by authorized qualified the input terminals and generates a proportional output signal of 0 - 10 V.
  • Page 9: Caractéristiques Techniques

    ® THERMASGARD ATM 2 Rev. 2017 - V12 FR Sonde de température extérieure étalonnable THERMASGARD ® ATM 2 avec convertisseur, huit plages de mesure commutables, capteur interne ou externe, sortie analogique, avec boîtier en matière plastique résiliente et vis de fermeture rapide, en option avec ou sans écran. Elle sert à la mesure de la température extérieure, dans des locaux humides par ex.
  • Page 10 Convertisseur de mesure étalonnable avec sortie active Load resistance diagram PLAGES DE TEMPÉRATURE (TB): Diagramme de charge Lors de la sélection des plages de convertisseur, 4...20 mA il faut veiller à ce que la température maximale admissible de la sonde ⁄ du boîtier ne soit pas dépassée ! Température ambiante du convertisseur: –...
  • Page 11: Montage Et Installation

    Montage et installation Les raccordements électriques doivent être exécutés HORS TENSION. CONDITIONS DE RACCORDEMENT Veillez à ne brancher l’appareil que sur un réseau de très basse tension Sortie: 0 -10 V de sécurité. Nous déclinons toute responsabilité ou garantie au titre de La tension de sortie est linéaire en fonction du signal de température appliqué...
  • Page 12: Технические Данные

    ® THERMASGARD ATM 2 Rev. 2017 - V12 RU Калибруемый наружный измерительный преобразователь температуры THERMASGARD ® ATM 2 с 8 переключаемыми диапазонами измерения, встроенным или внешним датчиком, аналоговым выходом, корпусом из пластика с высокой ударной вязкостью, крышкой корпуса с быстрозаворачиваемыми винтами, на выбор с дисплеем или без дисплея. Служит для измерения наружной температуры, температуры в помещениях с...
  • Page 13: Напряжение Питания

    Преобразователи измерительные, калибруемые, с активным выходом Load resistance diagram ТЕМПЕРАТУРНЫЕ ДИАПАЗОНЫ: Нагрузочная диаграмма При выборе диапазона для измерительного преобразователя 4...20 мA следует учитывать, что не разрешается превышение максимальной допустимой температуры датчика  ⁄ корпуса ! Температура окружающей среды для измерительного преобразователя: –...
  • Page 14: Монтаж И Подключение

    Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Подключе- УСЛОВИЯ ПОДКЛЮЧЕНИЯ ние должно осуществляться исключительно к безопасно малому на- Выход: 0 - 10 В пряжению. Повреждения приборов вследствие несоблюдения упомя- Выходное напряжение линейно зависит от сигнала температуры на входе и нутых...
  • Page 15 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r ATM 2 THERMASGARD ®  Anschlussbild ATM 2 - U Anschlussbild * ATM 2 - I DIP-Schalter DIP-Schalter Kontakt- Kontakt- Messbereichs- Messbereichs- seite seite umschaltung umschaltung 1 2 3 1 2 3 interner Sensor interner Sensor min. max.

Table des Matières