Plumbing - Honeywell TrueDRY DR65 Guide D'installation

Masquer les pouces Voir aussi pour TrueDRY DR65:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Install to Fit Your Application (continued)
C
Main Return to Main Return
RETURN
D
Dedicated Return to Dedicated Supply
SEPARATE

Plumbing

6
AIR HANDLER
TrueDRY
TrueDRY
RETURN
Ideal when...
SUPPLY
M27325
Ideal when...
SUPPLY
M33152
Attach 3/4-in. male NPT drain nozzle.
Connect 1/2-in. drain tube to male connection drain outlet.
Secure drain tube to connector with hose clamp.
Run drain hose continuously downhill to an approved drain or
condensate pump.
The drain line must include a water trap to prevent air from
entering or exiting the dehumidifier.
TrueDRY™ DR65 Dehumidification System 69-2089EFS—14
Running TrueDRY DR65 with A/C
operation.
System fan must run with dehumidifier.
Minimizing discharge air temperature
(DAT) increase is preferred.
Access to a dedicated central return for
TrueDRY DR65 is not available.
TrueDRY DR65 will not be ducted to a
forced air HVAC system.

Publicité

Table des Matières
loading

Table des Matières