Schémas - Crest 100 Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

12
Schémas
Figure 12-1 Schéma en échelle modèles 1000 - 2000
Chassis
Panel
Ground
Ground
Gnd
N
GD-1
GD-2
GD-3
GD-4
GD-5
GD-6
AD-1
AD-2
AD-3
AD-4
AD-5
AD-6
F1-4
F1-2
Blower
F1-1
F1-5
Service
Outlet
Blower Power
Relay Contacts
(NO)
CN1-2
CN1-1
CN4-1
CN4-2
CN4-3
O2 Board
CN3-1
CN3-3
CN3-5
CN3-6
L
On/Off
Switch
Figure 12-2 Schéma électrique modèles 1000 - 2000
480V – 3ø
L1
L2
L3 GND
GN
W
Chassis
Service
Ground
Outlet
Panel
Ground
BK
W
On/Off Switch
CF 24Vac Xfmr
BK
W
BL
BC/CC 24Vac Xfmr
BK
BL
R
BK
Y
W
Y/BK
HMI 24Vac Xfmr
BK
BL/BK
W
BK
Contactor
Coil
120V
GN
480V
Xfmr
BK
R
Panel
Ground
Contactor
BL
R
BK
BK
W
Power
F1-1
24Vdc+
F1-2
Tach
Blower
----
F1-3
PWM
F1-4
24Vdc-
F1-5
BK
Igniter
Spark Xfmr
Flame Sense 2
Flame Sense 1
X9-1
X9-2
X9-3
X9-4
X9-5
X9-6
X8-1
X8-2
X8-3
X8-4
X8-5
CF950
X8-6
X3-1
X3-3
X3-5
X3-8
X5-1
X5-4
CF 24Vac Xfmr
X4-1
X5-3
X4-4
X5-6
X4-2
X4-5
X12-1
X12-2
X12-3
O2 SENSOR
Air Temperature
Sensor
GY
BR
BK
T
Y
Y
R
Fan Control
Sensors
Gas Damper
Air Damper
W/BK
(A)
X12-1
(B)
X12-2
BC COMs
(RS485)
REF
X12-3
O2 Sensor
Power
X12-4
Main 24 Vac
REF
X11-1
Sakura
CF Rx
X11-2
COMs
CF Tx
X11-3
5V TTL
----
X11-4
Y/R
BL/R
BL
Y
GY
W
O
R
BK
Y
BK
BL
CF COMs
X1-24 Vac Supply & PE
(RS485)
X4 – Blower
X15-Switch Inputs
BC950
R
X6 – (Ign/Flame)
X7 – (GV 1&2)
BK
W
W
BK
BK
W
BK
R
PK
W
Blower
Blower
Relay Coil
X3-1
Inlet
Sensor
X3-3
X3-2
Outlet
X3-6
Sensor
X3-4
X3-12
Flue
X3-8
Sensor
X1-2
X3-9
X1-6
X1-1
X2-2
Blk Air Sw
X1-5
X2-1
Air Prove Sw
X1-4
X2-7
X1-8
X2-9
MRHL
X2-8
Panel
Dual Fuel Sw
Ground
X2-10
X2-11
HGPS 1
X2-15
LGPS 2
X2-12
X2-16
LWCO
LWCO Test
X10-1
(NC Momentary)
BC950
Probe
X10-2
X11-1
X10-3
X11-2
X15-2
X11-3
X2-8
X7-4
X2-9
X7-1
X7-2
X7-5
X2-13
P.O.C
A
P.O.C
B
X2-15
X6-4
X6-1
X15-1
Blkd Drain Sw
X6-2
X15-3
X6-5
X6-3
X15-5
X6-6
X15-4
Flue Damper Prv
Spark Xfmr
Flame
Flame
Sense 1
Sense 2
Igniter
GN
Y
GY
BR
BK
R
GN
AD-1
S B
GD-1
S B
Y
AD-2
GD-2
S A
S A
GY
AD-3
M B
GD-3
M B
BR
AD-4
M A
GD-4
M A
BK
AD-5
GND
GD-5
GND
R
AD-6
GD-6
+24Vdc
+24Vdc
CN4-3
Rx
CF COMs
CN4-2
CN3-1
Tx
Heater -
5V TTL
CN3-2
----
CN4-1
GND
GND
Heater +
CN3-3
"Sakura"
----
CN3-4
BK
O2 Board
CN3-5
AF-
R
CN3-6
AF+
CN1-2
Gnd
12 Vdc
CN1-1
Pwr
+12V
R
BK
R
BK
GND
Y/BK
BL/BK
GND
BK
R
CC COMs
(RS485)
Y
Inlet Sensor S2
X3-1
BL
Inlet
BL
Sensor
Sensor COM
X3-3
Y
X3-2
R
Outlet Sensor S1
Outlet
X3-6
R/W
Safety Outlet Sensor S9
Sensor
Sensor COM
X3-4
Y
----
X3-5
----
X3-11
X3-7
----
Sensor COM
X3-10
Flue Sensor S3
X3-12
W
Flue
GY
Safety Flue Sensor S10
X3-8
Sensor
Sensor COM
X3-9
Y
X3-13
----
----
X3-14
Blk Air Sw
X2-2
PR
Blocked Air Sw
24 Vac
X2-1
O
Air Prove Sw
Air Proving Sw
X2-7
O/R
MRHL
X2-9
MRHL
R
X2-8
24 Vac
BL
Dual Fuel Sw
X2-10
O
Dual Fuel
----
X2-14
LWCO Probe
X2-16
O/BK
O/BK
LWCO Test
LWCO
----
X2-3
Probe
X2-4
(NC Momentary)
----
X2-5
----
----
X2-6
HGPS 1
Gas Pr Sw 1
X2-11
O
24 Vac
X2-15
BL
LGPS 2
Gas Pr Sw 2
X2-12
BR
Proof of Closure
X2-13
Dual Body Gas Valve
w/Proof of Closure
P.O.C.
BK
BK/W
A
P.O.C.
W
W/BK
B
Manuel d'installation et d'utilisation
HIGH VOLTAGE
24 V
LOW VOLTAGE
NOTES:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and
rated for a
minimum of 105°C. Exceptions: Replacement high voltage spark lead and shielded cables must be purchased from the factory. Use of a non-approved
spark lead
or shielded cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when
using diagrams to troubleshoot unit.
J2-1
J2-2
P-1
HMI
P-2
P-3
P-4
P-5
P-6
P-7
X3-6
X8-10
X8-9
X3-5
X8-8
X3-4
X8-7
X8-6
X8-5
X8-4
X9-4
RATE +
0-10VDC
X8-3
OUT -
X9-3
X8-2
X9-2
BOILER
+
0-10VDC
X8-1
PUMP OUT -
X9-1
X11-6
X1-1
X1-2
X11-2
X1-3
X4-4
X1-4
X11-5
X1-5
CC950
X11-1
X1-6
X4-8
X1-7
BC/CC 24Vac
X1-8
Xfmr
X1-13
X2-1
X1-14
X2-2
X1-15
X2-3
X1-16
X4-5
X4-1
X18-1
X4-2
X18-2
X4-7
X19-1
X4-3
X19-2
X4-6
X19-3
X19-4
X3-1
X3-2
X7-1
X7-2
X3-3
X7-3
X7-4
X7-5
BAS Board
X7-6
X7-7
X7-8
X7-9
X7-10
X12-1
X7-11
X12-4
X7-12
X12-5
X7-13
X7-14
BAS
SHIELD
B
A
HIGH VOLTAGE
24 V
OPTIONAL ITEMS
LOW VOLTAGE
DUAL SENSOR
SINGLE HOUSING
NOTES:
1. All wiring must be installed in accordance with: local, state, provincial and national code
requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be
replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high voltage spark lead and shielded cables
must be purchased from the factory. Use of a non-approved spark lead
or shielded cables can lead to operational problems which could result in non-repairable
damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual
components for proper connector block locations when using diagrams to troubleshoot unit.
O2 SENSOR
BK
R
W
X4-1
24 VAC
BL
X4-2
24 VAC
X4-3
X4-4
Xfermer N
X4-5
Flow Switch
X4-6
Jumper
X4-7
MRHL
X4-8
Xfermer L
BL
X11-1
L
Y
X11-2
N
X11-3
----
X11-4
----
Main
CC950
X11-5
24 Vac
L
"Comfort Control"
X11-6
N
Pump Relay Board
X11-7
----
P7-2
X11-8
L
N
----
SYSTEM
P7-1
Main
24 Vac
P6-2
X10-10
24 Vdc-
BOILER
P6-1
X10-9
DHW Pmp
P5-2
P1-1
X10-8
DHW ReC
BYPASS
P5-1
P1-2
X10-7
Bypass Vlv
P1-3
X10-6
----
P4-2
DHW
P1-4
P4-1
X10-5
24 Vdc+
RECIRC
P1-5
X10-4
----
P3-2
P1-6
DHW
P1-7
X10-3
Boiler Pmp
P3-1
X10-2
Sys Pmp
X10-1
----
Dogwood (HMI)
J2-1
N
Main
J2-2
24 Vac
L
CC COMs
5V TTL
X2-4
X2-3
REF
X2-2
(B)
X2-1
(A)
X3-6
BK
COM
Y
X3-5
Tx
O
X3-4
Rx
X3-3
(A)
CC950
X3-2
"Comfort Control"
(B)
X3-1
GND
O
Y
BK
BK
X12-1
GND
X12-2
X4-1
Y
----
X12-3
X4-2
O
----
X12-4
X4-3
Rx
X12-5
Tx
X4-4
BAS Board
X12-6
----
GN
BK
W
WARNING
BOX DEPICTS
!
OPTIONAL ITEMS
DISCONNECT POWER
BOX DEPICTS
DUAL SENSOR
BEFORE SERVICING
SINGLE HOUSING
Pump Relay
Board
P2-2
P2-1
RUN-TIME
CONTACTS
ALARM
CONTACTS
24VAC LOUVER
RELAY COIL
FRONT END
LOADING #1
FRONT END
LOADING #2
OUTDOOR
SENSOR
TANK
SENSOR
SYSTEM RETURN
SENSOR
SYSTEM SUPPLY
SENSOR
HMI 24Vac Xfmr
- BMS
0-10VDC
+ IN
- SYSTEM
0-10VDC
+ PUMP IN
TANK
THERMOSTAT
LOUVER
PROVING
FLOW
SWITCH
ENABLE 4
ENABLE 3
ENABLE 2
ENABLE 1
A
CASCADE 1
B
SHIELD
LADDER DIAGRAM
100341094 REV A
WARNING
BOX DEPICTS
!
DISCONNECT POWER
BOX DEPICTS
BEFORE SERVICING
X18-1
Ext. FL/LWCO
1
X18-2
Ext. FL/LWCO
2
X18-3
MRHL
3
X18-4
MRHL
4
3WV
X8-13
X8-12
3WV
3WV
X8-11
Alarm
X8-10
RUN-TIME
X8-9
CONTACTS
Alarm
Run�me
X8-8
ALARM
X8-7
CONTACTS
Run�me
Lvrs Rly
X8-6
24VAC LOUVER
Lvrs Rly
X8-5
RELAY COIL
X8-4
FEL #1
FRONT END
FEL #1
X8-3
LOADING #1
FEL #2
X8-2
FRONT END
X8-1
FEL #2
LOADING #2
Rate COM
X9-4
+ RATE
0-10VDC
Rate 0-10V
X9-3
- OUT
BlrP COM
X9-2
+ BOILER
0-10VDC
X9-1
- PUMP OUT
BlrP 0-10V
X1-1
COM
OUTDOOR
Otdr-S5
X1-2
SENSOR
COM
X1-3
TANK
X1-4
Tank-S4
SENSOR
COM
X1-5
SYSTEM RETURN
SysRt-S7
X1-6
SENSOR
X1-7
COM
SYSTEM SUPPLY
SysSp-S6
X1-8
SENSOR
X1-13
0-10 BMS
- BMS
0-10VDC
0-10 BMS
X1-14
+ IN
Sys Pmp In
X1-15
- SYSTEM
0-10VDC
X1-16
Sys Pmp In
+ PUMP IN
X19-1
MRHL
1
X19-2
MRHL
2
X19-3
MRHL
3
X19-4
MRHL
4
DHW Tstat
X7-1
TANK
X7-2
THERMOSTAT
24 Vac L
Lvr Prv Sw
X7-3
LOUVER
X7-4
24 Vac L
PROVING
Flow Sw
X7-5
FLOW
24 Vac L
X7-6
SWITCH
X7-7
Enable 4
ENABLE 4
24 Vac L
X7-8
X7-9
Enable 3
ENABLE 3
24 Vac L
X7-10
Enable 2
X7-11
ENABLE 2
X7-12
24 Vac L
Enable 1
X7-13
ENABLE 1
X7-14
24 Vac L
GND
X14-1
SHIELD
A
X14-2
A
B
X14-3
B
X14-4
X14-5
X14-6
X5-3
A
(A)
X5-2
(B)
B
Ref
SHIELD
X5-1
WIRING DIAGRAM
100341093 REV A
67