Honeywell
3.2 Storage
Store the device in a dry and dust-free location.
Avoid constant direct sunlight.
Store the device in its original packaging.
Storage temperature: -25 to +70°C / -13 to +158°F.
3.3 Transport
INFORMATION!
Do not lift the measuring instrument by the index.
3.4 Requirements to be met before installation
Remove sealing caps and foils.
Check the meter and accessories for signs of transport damage.
Check that the turbine moves easily by generating a gentle air current.
Ensure that you have all the tools you require available.
Check that all the accessories are present (e.g. plug connectors, oil for
initial filling).
Seals which are suitable for your operating medium (see Table 4 for
examples). Please also check whether you must comply with other
standards, e.g. DIN EN 1591, Parts 1 – 4.
Table 4 | Suitable seals and gaskets
20
DN
d1 [mm]
50
62
80
100
100
125
150
178
73018696f
© Elster GmbH | All rights reserved. Subject to modification
The following seals and
gaskets, among others, are
suitable:
- flat seals
- spiral-wound gaskets
- grooved seals and gaskets