TROUBLESHOOTING
Problem: Water runs continuously
Possible Cause
Interfering object is in
monitoring range
Defective electronics module
Improper electronics module
External water pressure too high
Solenoid valve inoperable
Problem: Water flows although shut-off screw is removed
Possible Cause
Electronics module is inoperable
Water drops on infrared window
Problem: Faucet turns on by itself
Possible Cause
Infrared window is dirty or scratched Clean window with smooth cloth
Faucet is influenced by
room environment
(mirror, stainless steel or
glass sink, etc.)
Input line pressure fluctuates
Problem: Faucet is leaking water
Possible Cause
Connections between housing
and braided
Connection between braided hose Check rubber washers
and inlet supply are loose
Connection between valve body
and solenoid valve is loose
Faucet drips, solenoid valve
does not close
Problem: Temperature can not be adjusted properly
Possible Cause
No, or too little hot or cold water.
Supply valves are not fully opened
Inlet water line filter is dirty
or blocked
Braided hose is kinked
Backflow preventer in faucet
inlet is blocked
Temperature of hot or cold water
supply is too low
Hot water temperature not sufficient Reverse hot water limiter
Braided hoses are connected
improperly (cold to hot & hot to cold
18
Solution
Remove object from monitoring
area. Remove and re-install shut-off
screw. Do not disturb sensor
scanning procedure (wait until water
flow stops and LED switches off)
Replace electronics module
See "Replacement Parts"
Change mode or reset sensor
See "Care and Maintenance"
Check external water pressure
Provide pressure between 20 - 125 psi
Replace solenoid valve
See "Replacement Parts"
Solution
Replace electronics module
See "Replacement Parts"
Clean window with smooth cloth
Solution
Reset monitoring range
Remove and re-install shut-off
screw. Do not disturb sensor scan
ning procedure (wait until water flow
stops and LED switches off) Adjust
upper and lower beam to
compensate for reflections (Geberit
Commander™ software required.
Go to "www.chicagofaucets.com/
commander" for details)
Install appropriate line
pressure regulators
Solution
Check O-rings
Replace O-rings when damaged
or missing
Replace washers when damaged
or missing
Check O-rings - Replace O-rings
when damaged. Carefully re-installed
solenoid valve & do not overnighten
Clean or replace solenoid valve
See "Replacement Parts"
Solution
Full open supply valves
Clean or replace filter
See "Care and Maintenance"
Eliminate braided hose kink
Unblock backflow preventer
Check inlet water temperature
or inspect boiler
See "Care and Maintenance"
Correct the connections

CARE AND MAINTENANCE

Faucet Adjustments
Operating modes and sensor ranges can be adjusted with a manual
operation through the infrared sensor. A traditional lavatory faucet is
shown as an example. Faucet adjustment operations apply to all models.
Alternatively, operating modes and sensor ranges can be adjusted with
a handheld PDA and Geberit Commander
information, visit our website at www.chicagofaucets.com/commander.

OPERATING MODES

Operating Modes
A: Cleaning Mode
B: Normal Mode
C: Metering Mode (10 s)
D: Scrub Mode (60 s)
E: Scrub Mode (180 s)
F: Sensor Range Adjustment
G: Reset
In order to set the operating modes, the faucet needs to be placed into
"Manual Setting" mode. At this time, operating modes can be changed
within the next 30 minutes.The following is a functional diagram to show
the different settings available for manual faucet adjustment.
FUNCTION DIAGRAM OF OPERATING MODES
Water pulses in seconds [s]
Modes
5
A - Cleaning Mode
B - Normal Mode
C - Metering Mode 10 s
D - Scrub Mode 60 s
E - Scrub Mode 180 s
F - Sensor Range Adjustment
Legend:
Water is off
Water is on
software. For more
Description
The faucet is inactive for 90 seconds.
The faucet is activated if it senses a
hand presence. This is the default
operating mode of the faucet.
The faucet will shut off after 10 seconds
regardless of hand presence detected.
The faucet will shut off 60 seconds after the
detection of the last hand presence.
The faucet will shut off 180 seconds after
the detection of the last hand presence.
Change the detection distance of the
infrared sensor. The default sensor range
is approximately 1" beyond the spout.
All settings will be reset to original factory
settings.
4
1 4
1 4
1 4
1 4
1
19