Attachment to the ceiling
The heating panel must be at least 20 cm from all objects, walls and so on. The
minimum distance from the ceiling is 4 cm as this allows an airflow which will prevent the
heating panel from overheating. The minimum distance from the bottom of the heating
panel to the floor must be 185 cm. Choose a sturdy, even ceiling made of heat-proof
material for hanging the heating panel.
Step 1:
Use the H-bracket to mark the holes in the ceiling
Position the H-bracket such that, when the heating panel is installed, the
minimum distances above are guaranteed. Make sure that the hanging
frame is installed with the correct side to the top. (see diagram)
Check and make sure that there are no cables in the ceiling before
drilling at the marked points.
Step 2:
Drill holes with an 7 mm drill bit
Step 3:
Push the plugs into the holes
Step 4:
Secure the screws with the O-rings in the plugs through the holes in the H-
bracket
Step 5:
Mount the panel on the bracket and ensure that the panel is secured as
shown in image 5.