Action to be taken:
1. Connect the SMP to the battery using the supplied cables and switch on the charger using the
switch on the back.
2. Adjust the voltage level to 67,2 V using the VOLTAGE knob.
3. Adjust the current level to 4,0 A using the CURRENT knob.
Note! Please have in mind that this charger will limit the output power to 800W.
The top display will now show the actual voltage level that slowly will increase towards the adjusted
level of 67,2 V, however only in very rare cases. In the meantime the lower display will show the
adjusted current level of 4,0 A. To verify the set values, press the SET button.
The de-sulphating process is only ready when battery voltage and specific gravity is stabilised. In
cases when only the weekends are available for de-sulphating you can continue the following
weekend.
If you require any further information or assistance please do not hesitate to contact the local
Micropower representative or Micropower directly.
Technical Specification
Mains supply:
Current draw:
Power factor:
Max. Current:
Max. Voltage:
Max. Power: 800W
Max. Ripple out:
Efficiency:
Frequency:
Cooling:
Weight:
Dimension:
Protection:
Cables:
9904111 Issue 4
220-240VAC 50-60Hz (90-200 power limited)
4,5A
~1 (PFC)
120/10
10A
120V
30mV RMS
>86%
>100kHz
Temp. Controlled fan
1,6kg
258 x 136 x 89mm
IP21, Electrically II (with or
Without earth.
One set of laboratory cables
Is included.
7