12 www.electrolux.com
with the voltage and the power of the
local power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug which can hold the load that
the rating plate rates. Make sure that
you install the plug in a correct socket.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to
the mains plug after the installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• There is a risk of fire when the appli-
ance is in connection with an extension
cable, an adapter or a multiple connec-
tion. Make sure that the ground con-
nection agrees with the standards and
regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect the blue neu-
tral cable to the terminal with a letter "N"
on it. Connect the brown (or black) phase
cable to the terminal which has a letter
"L". Keep the phase cable connected at
all times.
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building In
min. 650 mm
55 mm
If several 30 cm hobs are to be installed
side by side into the same cut out, an as-
sembly kit including a support side brack-
490 mm
40-50 mm
30 mm
et and supplementary seals is available at
our Service Centres. The relevant installa-
tion instructions are supplied within the kit
package.
A)
supplied seal
B)
supplied bracket
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.7 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
60 mm
A)
Removable panel
B)
Space for connections
270 mm
B
30 mm
min 20 mm
A
(max 150 mm)
B
A