6900
Table of primary and respective secondary ID codes:
Primary
Secondary ID
ID
1
2
3
1
51
52
53
2
54
55
56
3
57
58
59
4
60
61
62
5
63
64
65
6
66
67
68
7
69
70
71
8
72
73
74
9
75
76
77
10
78
79
80
11
81
82
83
12
84
85
86
13
87
88
89
14
90
91
92
15
93
94
95
16
96
97
98
17
99
100
101
18
102
103
104
19
105
106
107
20
108
109
110
21
111
112
113
22
114
115
116
23
117
118
119
24
120
121
122
25
123
124
125
Important: Delete from Group: to delete from a group, the
programming deletion procedure described in the "Deleting
programming" section must be carried out (all programming
deleted).
Button programming
Important: without programmer 950C or SaveProg software,
the only functions that can be assigned are intercommunica-
ting, specific entrance panel self-activation, restoring buttons
programmed by the installer to their default settings and dele-
ting all programming procedures performed.
E1
E2
D
C
16
Primary
Secondary ID
ID
1
2
26
126
127
27
129
130
28
132
133
29
135
136
30
138
139
31
141
142
32
144
145
33
147
148
34
150
151
35
153
154
36
156
157
37
159
160
38
162
163
39
165
166
40
168
169
41
171
172
42
174
175
43
177
178
44
180
181
45
183
184
46
186
187
47
189
190
48
192
193
49
195
196
50
198
199
E4
E5
E3
E6
Programming intercommunicating call buttons
To program the buttons, proceed as follows:
1) Press "speak/listen" or lift the handset (depending on the
model installed) of the interphone you wish TO CALL.
3
2) Press and hold button B on the interphone you wish to
128
program (making the call).
131
3) Press and hold button A at the same time.
134
4) Wait for the RED LED to flash.
137
5) Release buttons A and B.
140
6) Press and hold the button you wish to program (e.g. E1, E2,
143
E3, E4, E5, E6).
146
7) Wait for the interphone to emit a chime.
149
8) Release the button you wish to program on the interphone
152
making the call.
155
9) Press a button (lock/F1/F2) on the interphone you wish
158
to call.
161
10) A "note" on the interphone (making the call) being pro-
164
grammed confirms the setting has been saved.
167
170
Important: This procedure can be used to manually repro-
gram the buttons, with the exception of the speak/listen button
173
(not programmable) and the lock and self-start buttons (for
176
which programmer 950C or SaveProg software is required).
179
182
Programming the self-activation/self-start button
185
188
to a specific panel
191
(different from the self-start function enabled using button
194
"A")
197
1) Press and hold button B.
200
2) Press and hold button A at the same time.
3) Wait for the RED LED to flash.
4) Release buttons A and B.
5) Press and hold the button you wish to program (excluding
speak/listen, lock and self-start).
6) Wait for the interphone to emit a tone.
7) Release the button.
8) For entrance panels with buttons, press the button corre-
sponding to the monitor on which the button is being saved.
For alphanumeric entrance panels, enter the ID number
corresponding to the monitor on which the button is being
saved, and confirm using the bell button on the entrance
panel.
9) At the end of the procedure described above, a sharp tone
will be emitted by the interphone, while the entrance panel
makes a call to the interphone on which programming has
taken place.
Reprogramming the default value separately for
each button
A
1) Press and hold button B.
2) Press and hold button A at the same time.
B
3) Wait for the red LED to flash.
4) Release buttons A and B.
5) Press and hold the button for which you wish to restore
the default setting (does not apply to Self-start and Lock
buttons).
6) Wait for the interphone to emit a tone.
7) Release the button.
8) Press the button again (it will now be restored to its default