Installation Safety; General Safety Instructions; Instructions, Standards And Regulations; Eu Conformity And Ecodesign Directive - wodtke FEEL WARM IR 300 Instructions De Montage

Chauffage radiant infrarouge
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Installation • Safety

Installation

7. Safety
Only a qualified contractor should carry out installation, com-
missioning, maintenance and repair of the appliance.

7.1 General safety instructions

- We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
- Fit the appliance to a vertical wall that is temperature-re-
sistant to at least 90 °C.
- Observe the minimum clearances to adjacent object
surfaces (for minimum clearances see chapter "Specifica-
tions / Minimum clearances").
- Never install the appliance directly below a wall socket.
- Select your installation location so that no sockets are in-
stalled on the surface concealed by the appliance.
- When installing the heating appliance in rooms with a
bath and/or shower, observe the safety zone according to
VDE 0100, part 701, in accordance with the details on the
appliance type plate. The mains junction box must not be
installed in safety zone 1 or 2 in this instance.
- Install the appliance in such a way that switching and con-
trol equipment cannot be touched by a person in the bath
or shower.
- Design all materials in accordance with the rated con-
sumption of the appliances.
- When selecting an installation site; ensure that no persons
or objects can come to harm if the toughened safety glass
spontaneously breaks.

7.2 Instructions, standards and regulations

Note
Observe all applicable national and regional regula-
tions and instructions.

7.3 EU conformity and Ecodesign Directive

As of 01/01/2018, the EU conformity of these appliances is ad-
ditionally dependent on compliance with ecodesign require-
ments.
These appliances may only be installed and commissioned in
conjunction with external room temperature controllers that
have the following functions:
- Electronic room temperature control and day of week
control
- Adaptive control of the start of heating
Suitable controllers can be found in our pricelist.
Failure to observe these requirements will result in the loss of
the CE designation.
© wodtke GmbH - Tübingen.

8. Appliance description

8.1 Standard delivery

The following are delivered with the appliance:
- 1 retaining bracket
- IR...300-500: 1 wall mounting bracket
- IR...700-900: 2 wall mounting brackets

8.2 Required accessories

Only use the appliance in conjunction with the room tempera-
ture controllers listed in chapter "EU conformity and Ecodesign
Directive".
9. Installation

9.1 Installation site

Material losses
!
Observe the minimum clearances (see chapter "Spec-
ification / Minimum clearances").
Material losses
!
The appliance is not suitable for mounting on ceilings
or inclines.
- The appliance is exclusively designed for installation on a
solid wall.
- Ensure the wall offers adequate load bearing capacity.
- The appliance can be mounted in any room. You may only
mount the appliance within protection zone 2 or higher in
bathrooms.
9.2 Wall mounting
Note
You can mount the appliance both vertically and hori-
zontally.
The ON/OFF switch position can be used to correctly
align the appliance:
- When mounted vertically, the ON/OFF switch is lo-
cated on the bottom edge of the appliance.
- When mounted horizontally, the ON/OFF switch
is located on the left outer edge of the appliance
when viewed from the front.
9.2.1 Wall mounting bracket
IR...300 | IR...500: The appliance comes with a wall
- The wall mounting bracket is used to mount the appliance
vertically or horizontally.
IR...700 | IR...900: The appliance comes with two wall
- The short wall mounting bracket is used to mount the ap-
pliance vertically.
- The long wall mounting bracket is used to mount the ap-
pliance horizontally.
IR_BA_190726
mounting bracket.
mounting brackets of different lengths.
Page 16 / 64

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Feel warm ir 500Feel warm ir 700Feel warm ir 900

Table des Matières