Rover PG Protections

Protection
Behavior
When PV shot circuit occurs, the controller will stop charging.
PV Array Short Circuit
Clear it to resume normal operation.
The controller will limit the battery charging current to the
maximum battery current rating. Therefore, an over-sized
PV Overcurrent
solar array will not operate at peak power.
If the current exceeds the maximum load current rating 1.05
times, the controller will disconnect the load. Overloading
Load Overload
must be cleared up by reducing the load and restarting the
controller.
Fully protected against the load wiring short-circuit. Once the
load short (more than quadruple rate current), the load short
Load Short Circuit
protection will start automatically. After 5 automatic load
reconnect attempts, the faults must be cleared by restarting
the controller.
The controller will not operate if the PV wires are switched.
PV Reverse Polarity
Wire them correctly to resume normal controller operation.
The controller will not operate if the battery wires are
Battery Reverse Polarity
switched. Wire them correctly to resume normal controller
operation.
If the temperature of the controller heat sink exceeds 65℃,
the controller will automatically start reducing the charging
Over-Temperature
current. The controller will shut down when the temperature
exceeds 85℃.