Page U
p/ Increase parameter value
Page Down/ Decrease parameter value
/ -
Return to the previous menu
Enter sub menu/ save parameter value/
ENTER/
turn load on or off in manual mode
Programming Parameters
Battery type
System voltage
Equalizing voltage
Boost voltage
Over-discharge
Over-discharge voltage
return voltage
Float voltage
To enter the programming interface simply press and hold the right arrow button. After entering
this feature press the Enter/Right button to switch between parameters. To change the
parameters, press the Up or Down button. To save the parameter press and hold the
Enter/Right button.
The charging parameter setting (Equalizing voltage, Boost voltage, Floating charging voltage,
over-discharge return voltage, Over-discharge voltage) are only available under the battery
"USER" mode. Press and hold the right arrow to enter the programming settings and continue
pressing the right arrow button until you see the desired voltage screen.
NOTE
Battery charging parameters can also be programmed using the Renogy BT APP. Read the
corresponding user manuals for more information.