4.2.4. CONTROL CONFIGURATION DEPENDING ON THE size of the area (m2) to be operated in
Preconfigured parameters of the purifier control. The user must select the setpoint depending on the m
where the unit is going to be installed.
AIR-TEK PRO 150
Surface
(m
)
2
15
30
45
60
75
85
AIR-TEK PRO 300
Surface
(m
)
2
60
75
90
105
120
125
Q max.
Setpoint
(m
/h)
3
100
23
200
41
300
54
400
67
500
84
567
99
Q max.
Setpoint
(m
/h)
3
400
53
500
61
600
70
700
81
800
95
833
100
Control voltage
Power
(V)
(W)
2,3
5,20
4,1
16,14
5,4
34,17
6,7
62,83
8,4
105,61
9,9
143,72
Control voltage
Power
(V)
(W)
5,3
33,38
6,1
52,48
7,0
78,23
8,1
111,72
9,5
154,10
10,0
170,39
of the area
2
Current (A)
0,23
0,27
0,40
0,62
0,94
1,22
Current (A)
0,37
0,51
0,70
0,96
1,29
1,42