After installing, and particularly if the door hinge is reversed, please ensure that the
door seal is tight all round. An imperfect door seal can lead to increased condensa-
tion and thus to higher energy consumption (see the section headed «What to do
if...»).
Electrical connection
A properly installed socket outlet with earthing contact is required for electrical con-
nection, positioned so that it is possible to pull out the mains plug.
The socket outlet with earthing contact used to connect the appliance should be
positioned on the left or right-hand side adjacent to the housing.
Electrical fuse protection of at least 10/16 amperes must be provided. If the socket
is no longer accessible once the appliance has been built-in, suitable measures
must be taken during electrical installation to ensure that the appliance can be dis-
connected from the mains (fuse, LP [line protection] contact opening width of at
least 3 mm).
The identification plate is located inside the appliance on the top right-hand side.
Before operating the appliance, check the identification plate to ensure compliance
of the connection voltage and type of current with the mains network values at the
installation site.
e.g. AC
220 ... 240 V
220 ... 240 V~
(i.e. 220 to 240 volt alternating current, 50 Hertz)
50
50 Hz or
50 Hz