PERIODIC CLEANING OF THE BOILER
·
To maintain optimum performance, clean the boiler every 10/20 uses depending on the amount
of limestone in the water.
·
Disconnect the appliance and let it cool down for at least 2 hours.
·
After the appliance refrigeration enough put up one side of the cleaning valve (11), forced to
rotate counterclockwise the cleaning valve (Fig.5) (do not lie flat the appliance when you open
the cleaning valve, otherwise the water will leakage).
CAUTION! Never attempt to open the cleaning valve (11)while the boiler is under pressure.
CAUTION: do not pour more than 200ml water into the boiler. Pour water slowly, being careful
not to let it overflow, as this could damage the appliance.
·
Rinse out the boiler and pour the water away into the sink or into a container for collecting dirty
water.
·
If the water is very dirty, repeat the operation until it is clean.
·
Checking that the seal is present and that the cap is screwed on properly.
·
Fill the water tank again.
·
Turn the appliance on again.
·
Before ironing, release steam into the sink or another container and check that the steam is
clean. This should take a few seconds.
·
Resume ironing normally.
TROUBLESHOOTING
PROBLEM
Water comes out of the iron
instead of steam
The appliance is on but it is not
producing steam
CAUSE
The appliance has not reached
the right temperature yet.
The temperature control dial
has set at the minimum.
Water tank is empty or not
inserted correctly.
SOLUTION
Wait for the "Steam Ready"
indicator light and the iron
indicator light to turn off.
Increase the regulation of the
temperature control dial.
Fill the water tank.