User Manual
EN
Quadra Pro head - N° 20121
BATTERY INFORMATION
•
The battery can be charged at an ambient temperature from 0°C to +45°C, if the temperature
is exceeded, the safety circuitry of the battery will shut down to avoid damage to the Li-Ion
cells.
•
There is no memory-effect; our Lithium-Ion battery can be recharged from any charge level.
•
A completely charged battery will need to be recharged latest every 3 months.
•
Please refer to the battery guide to know how to take care of your battery in the best possible
way.
BATTERY FUSE
The battery is secured with an ATO 20 A fuse. The topside of the battery includes transport
pockets for two spare ATO 20 A fuses. When travelling by air and in general, remove the fuse to
deactivate the battery and place the fuse into the free transport pocket!
1.
Insert the 20 A fuse into the battery.
2.
First connect the Elinchrom Li-Ion charger with the battery, and then connect the charger to
the mains.
3.
Charge the battery until the Elinchrom Li-Ion charger status light turns to green.
4.
Press the battery button to check if the battery capacity is at 100% (4 green LEDs).
5.
Remove first the mains connection, and then remove the charger from the battery.
BATTERY STATUS
The Li-Ion battery implements a full-integrated monitoring circuitry, which
allows the user to know exactly the available capacity of the battery when
pressing the push button, located on the front of the battery LED's.
75% -100%
50% -75%
25% - 50%
10% - 25%
< 10%
12
flashes
Quadra Action head - N° 20151