WORKING SETPOINT AND CONFIGURATION PARAMETERS (TOP COMPARTMENT)

Setting the working setpoint
• press
LED
• press
or
• after changing the value, confirm by pressing
You also can modify the working setpoint through parameter SP.
Working setpoints
LABEL
MIN.
MAS.
r1
r2
Setting configuration parameters
To gain access the procedure:
• make sure no procedure is running
• press
and
• press
• press
or
• press
or do not operate 15 s
• press
and
To select a parameter:
• press
or
To modify a parameter:
• press
• press
or
• press
or do not operate 15 s.
To quit the procedure:
• press
and
Configuration parameters
LABEL
MIN.
MAS.
SP
r1
r2
LABEL
MIN.
MAS.
CA1
-25
25
P0
0
1
P1
0
1
P2
0
1
LABEL
MIN.
MAS.
r0
0.1
15
r1
-99
r2
r2
r1
99
LABEL
MIN.
MAS.
C0
0
240
C2
0
240
LABEL
MIN.
MAS.
d0
0
99
d3
0
99
d4
0
1
d5
0
99
d6
0
1
(1) the unit of measure depends on parameter P2
(2) set the parameters related to the regulators appropriately after themodification of the parameter P2
(5) the modification of parameter d0 has effect since the end of the previous defrost interval or since the activation of a defrost by hand
(6) the display restores the normal operation as soon as the defrost ends and the cabinet temperature falls below the one that has locked the display (or if a
temperature alarm arises)
will flash
, within 15 seconds to change the temperature value.
U.M.
DEF.
°C/°F (1)
0
4 s: the display will show "PA"
in 15 s to set "-19"
4 s: the display will show "SP"
in 15 s
4 s or do not operate 60 s.
U.M.
DEF.
°C/°F (1)
0
U.M.
DEF.
°C/°F (1)
-1
-
1
-
0
-
0
U.M.
DEF.
°C/°F (1)
2
°C/°F (1)
2
°C/°F (1)
10
U.M.
DEF.
min
0
min
3
U.M.
DEF.
H
0
min
0
-
0
min
0
-
1
, or avoiding any operation for 15 seconds.
WORKING SETPOINTS
working setpoint
WORKING SETPOINTS
working setpoint
MEASURE INPUTS
cabinet probe offset
kind of probe
(0=PTC, 1=NTC)
decimal point Celsius degree (for the quantity to show during the normal operation) (1=
YES)
unit of measure temperature (2)
MAIN REGULATOR
working setpoint differential
minimum working setpoint
maximum working setpoint
COMPRESSOR PROTECTIONS
compressor delay since you turn on the instrument
minimum time the compressor remainsturned off
DEFROST
defrost interval; also look at d8 (5)
0=the defrost at intervals will never be activated
defrost duration (0=the defrost will never be activated)
defrost when you turn on the instrument
defrost delay when you turn on the instrument (only if d4 = 1)
temperature shown during the defrost
0=cabinet temperature1=if to the defrost activation the cabinet temperature is below
"working setpoint+ r0", at most "working setpoint + r0"; if to the defrost activation the
cabinet temperature is above "working setpoint +r0", at most the cabinet temperature to
the defrost activation (6)
(0=°C, 1=°F)
(1=YES)
10