EN
2 / INSTALLING YOUR APPLIANCE
Ducting mode
•
Install the wiring system and prepare the air
venting hole.
Insert the appliance in the hole (Fig. 5).
Tighten the 2 screws inside the appliance (Fig. 8)
until it fits snug on the bottom of the wall unit. Do not
tighten the 2 screws strongly, to maintain the
metallic clamps in the right position.
Connect the air evacuation tube with the device air
outlet: use a flexible tube and block it in the device
air outlet through a metallic clamp (the tube and the
clamp are not provided).
Make the electrical connection of the hood by
means of the power supply cable.
Non-return valve
If installing the ducting version, fitting the
non-return valve hinders air intake and return.
Before securing the valve, check that the tabs
can move freely (Fig. 7).
Warning
This is the filtering version of your cooker
hood; you must first remove the charcoal
filter.
Tip
For optimal use of your appliance, we
recommend that you connect the hood to a
150 mm-diameter flue (not delivered with the
appliance). Minimise the number of angles
and bends and the lengths of the flue. In
the event that the hood will be operated
using out-door evacuation, you should
ensure a sufficient inflow of fresh air to
avoid a pressure deficiency in the room.
Fig.7
24
Fig.6
Fig.7a
Fig.8