Get-Function Listing - ViewSonic CDM5500T Guide De L'utilisateur

Table des Matières

Publicité

Mute
8
Button Lock
8
Menu Lock
8
Key Pad
8
Remote Control
8
Factory reset
8

10.3.2. Get-Function Listing

The PC can interrogate the TV/DS for specific information. The Get-Function packet format consists of 9
bytes which is similar to the Set-Function packet structure. Note that the "Value" byte is always = 000
Get-Function description:
Length:
Total Byte of Message excluding "CR".
TV/DS ID
Identification for each of TV/DS (01~98; default is 01).
Command Type
Identify command type,
"g" (0x67h) : Get Command
"r" (0x72h) : Valid command Reply
"-" (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code.
Value[1~3]:
Three bytes ASCII that defines the value.
CR
0x0D
Get-Function format
Send: (Command Type="g")
Name
Length
Byte Count
1 Byte
Bytes order
1
NOTE: "Power STBY status" is the exception for VT2405LED-1 and VT3205LED.
s
6
s
8
s
>
s
A
s
B
s
~
Command
ID
Command
Type
2 Byte
1 Byte
2~3
4
36
000: OFF
001: ON (mute)
38
000 : Unlock
001 : Lock
3E
000 : Unlock
001 : Lock
41
000 : UP
001 : DOWN
002 : LEFT
003 : RIGHT
004 : ENTER
005 : INPUT
006 : MENU/EXIT
42
000: Disable
001: Enable
002: Pass through
7E
0
Value1
1 Byte
1 Byte
5
6
40
Disable: RCU has no
effect on Monotor.
Enabled: RCU controls
the Monitor. This is the
power up default on the
Monitor.
Pass through: RCU
has no effect on
Monitor and all RCU
command codes are
transmitted to PC via
the RS232 port.
Rests Monitor to
factory setting
Value2
Value3
1 Byte
1 Byte
7
8
CR
1 Byte
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vs16854

Table des Matières