Waste discharge pressure stops or decreases dramatically.
The pump operates, but no liquid is expelled.
The motor will not run.
The pump turns off on its own.
How do I disassemble the system to check for an object lodged
in the pump?
Warranty
For defi ned warranty terms, review the one-page warranty
statement - see www.thetford.com.
Please give Serial Number (located on the tank sticker)
NOTICE
for calls to customer service and warranty issues.
®
SANICON
Turbo - Model 700
Troubleshooting
roubleshooting
Problem
Are the holding tanks empty?
With pump on, look for location where hose expansion
differs; check for obstruction at that point.
Turn the pump switch to the Off position:
To CHECK FOR OBSTRUCTION IN HOSE (
Check for foreign matter lodged in the hose by
running your hand along hose to detect variation in
hose width.
TO CHECK FOR OBSTRUCTION IN IMPELLER:
Look through clear access cap (
obstruction.
NOTICE
Failure to clear a clog could cause damage to the
pump, which will void the warranty.
Are the holding tanks empty?
Check that the RV gate valves are open.
Pump may be clogged.
Make sure:
Pump is turned on.
RV battery is charged.
Circuit breaker/fuse is functioning.
Pump is receiving voltage.
Foreign object is not preventing impeller operation
See "Thermal Cut-Off Switch" topic under "Overview" sec-
tion of this document.
Refer to "Obstruction Removal" topic in "Operation" section of
this document.