Télécharger Imprimer la page

Steinbach Speedcleaner RX5 Instructions De Service page 8

Masquer les pouces Voir aussi pour Speedcleaner RX5:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
EN
Caution: There is a positioning pin on the top of the filter housing,
please do not mount this incorrectly! Fig. 15.
After mounting the housing cover, the cover screws must be re-
fitted.
Caution: To avoid any negative effect on the performance of the
cleaner, make sure that the cover is properly attached to the base
housing. To avoid any damage, please make sure that the cable is in
the correct position. Fig. 16.
Function and description of the weight
The weight is located on the bottom of the housing, directly under-
neath the motor unit.
The angle of inclination on the pool wall is set by adjusting the posi-
tion of the slide, left or right. On delivery, the weight is adjusted to a
standard setting. We recommend that you do not move the weight
around unnecessarily. If cleaning performance is not satisfactory,
you can adjust this as follows:
The following adjustments to settings can be made:
b.) When the cleaner is operating in the water, the angle may
be too large, which can lead to an intake of air. If this is
the case, you can loosen the fixing screw and move the
weight away from the cable (higher figure). Do not push
the weight by more than 10-20 mm per test! Then re-
tighten the fixing screw.
Fig. 17.
A cable side facing upwards
b.) If the cleaner is not tilted enough (and always works on the
same side), you should loosen the fixing screw and push the weight
towards the cable (to the negative side of the scale) Then re-tighten
the fixing screw.
Fig. 18.
A adjustable weight
B fixed weight
If the cleaner tilts in the wrong direction (cable outlet is higher than
the mid-point), Fig, 19, then you should push the weight towards
the cable outlet. Move no more than 10mm at a time. Then re-
tighten the fixing screw.
c) If the cleaner tilts the wrong way (cable side upwards), then you
should move the weight up to 30-40mm towards the cable outlet. Fi-
nally re-tighten the fixing screw.
d) Wrong position, Fig. 20
A cable side facing upwards
e) correct position, Fig. 21
A cable side facing upwards
Hints and tips
Every time the cleaner is taken out of the water, the filter cleaner
must be cleaned.
Make sure the pH value of the water is between 7.0 and 7.2.
Make sure the water temperature is between 12°C and 32°C.
After every clean, the drive train must be thoroughly cleaned to en-
sure the same level of grip on the next clean.
After pressing the "Power Off" button, the "Power On" button cannot
be pressed for 30 seconds.
We recommend keeping the cleaner between 5°C and 40°C in a
shaded, well ventilated place. The mains cable should be coiled
around the cable holder for storage. (The floats must not be pushed
Page 8 of 58
along the cable to ensure the cable floats properly in the water.)
Avoid direct sunlight at all times.
We recommend attaching the operating unit with a safety rope, to
avoid any risk of the power pack being pulled into the pool.
Before use, please read the instructions relating to trouble-shooting
thoroughly.
Instructions for mounting the 4 locking plates on the cover
For pools with steps we recommend fitting locking plates to the cov-
er. These locking plates stop the cleaner from tipping.
Attach the stabiliser as shown in the photo. Fig. 22
Screw the screw in through the hole in the cover and tighten. Fig. 23.
Tighten the stabiliser with a Philips screwdriver.
Trouble shooting
Fault
Cause
The power ca-
Cable was not re-
ble is twisted
leased properly
or tangled
The cable in the wa-
ter is too long.
Cleaner is stuck on
the outlet grille
The
cleaner
The power unit is in
cannot
reach
the wrong place
all areas.
Water circulation in
the pool is switched
on.
Connection cable is
too short
Cleaner
does
Filter bag is blocked
not climb up
the pool wall
Algae is growing on
the walls
Water temperature is
too high / too low
Brushes are worn
The cleaner is too
light, it is tilting
PH value is not cor-
rect
The slide (weight ad-
justment) does not fit
or it is too loose.
Cleaner is not
Power pack is not ful-
operating
ly plugged in
The
cleaner
damaged
transport.
The
operating
needs
a
voltage to the local
one.
Cleaner
does
There is air in the
not sink
cleaner
Drive
roller
Foreign body in the
Solution
Switch off the unit, re-
lease and uncoil the ca-
ble.
Remove the excess ca-
ble from the water.
Switch off the filter unit.
Position the power unit
so that the cleaner can
reach all areas properly.
Switch off the filter unit.
Place the greatest possi-
ble length of connecting
cable into the pool, but
bear in mind the corre-
sponding minimum dis-
tance between the oper-
ating unit and the pool
Replace the filter bag
Clean the pool walls
Optimal water tempera-
ture is between 10°C and
32°C
Contact a dealer, replace
the brushes
Switch the unit off and al-
low the air to escape
Test the value to keep it
between 7.0 and 7.4
Reset to factory settings.
Check the power cable
and the operating unit.
was
Contact a specialist re-
during
tailer
unit
Contact a specialist re-
different
tailer
Switch the unit off, allow
the air to escape, and let
the cleaner sink to the
bottom.
Contact a specialist re-
Speedcleaner RX5 | 2015_V1

Publicité

loading

Ce manuel est également adapté pour:

061018