S+S Regeltechnik HYGRASGARD KFF Série Notice D'instruction

S+S Regeltechnik HYGRASGARD KFF Série Notice D'instruction

Masquer les pouces Voir aussi pour HYGRASGARD KFF Série:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

D G F r
6003-1900-2015-000 31900-2016 V101 07 ⁄ 2016
KFF - xx
HYGRASGARD
® 
KFTF - xx
HYGRASGARD
® 
D
Bedienungs- und Montageanleitung
Kanal- Feuchte- und Temperaturfühler (± 2 % ⁄ ± 3 %),
incl. Montageflansch, kalibrierfähig, mit Mehrbereichsumschaltung
und aktivem ⁄ passivem Ausgang
G
Operating Instructions, Mounting & Installation
Duct humidity and temperature sensors (± 2 % ⁄ ± 3 %),
including mounting flange, calibratable, with multi-range switching
and active ⁄ passive output
F
Notice d'instruction
Sonde d'humidité et de température (± 2 % ⁄ ± 3 %),
pour montage en gaine, y compris bride de montage, étalonnable,
avec commutation multi-gamme et sortie active ⁄ passive
r
Руководство по монтажу и обслуживанию
Датчик влажности и температуры канальный (± 2 % ⁄ ± 3 %),
вкл. присоединительный фланец, калибруемый,
с переключением между несколькими диапазонами
и активным ⁄ пассивным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
KFF ⁄ KFTF (± 3 % )
KFF - 20 ⁄ KFTF - 20 (± 2 % )
ohne Display
without display
sans écran
без дисплея
KFF ⁄ KFTF (± 3 % )
mit Display
with display
avec écran
с дисплеем
KFF - 20 ⁄ KFTF - 20 (± 2 % )
mit Display
with display
avec écran
с дисплеем
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.

Publicité

Table des Matières
loading

Sommaire des Matières pour S+S Regeltechnik HYGRASGARD KFF Série

  • Page 1 с дисплеем KFF - 20 ⁄ KFTF - 20 (± 2 % ) mit Display with display avec écran с дисплеем S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄ GERMANY You have bought a German quality product.
  • Page 2 D G F r KFF - xx HYGRASGARD ®  KFTF - xx HYGRASGARD ®  Maßzeichnung KFF - xx Dimensional drawing KFTF - xx Plan coté (Tyr 1) Габаритный чертеж ohne Display mit Display without display with display sans écran avec écran без...
  • Page 3: Technische Daten

    ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Rev. 2016 - V23 DE Qualitätsprodukt für HKL-Bereich, Genauigkeit ± 2 % bzw. ± 3 % Kalibrierfähiger Kanal-Feuchte- ⁄ Temperatursensor HYGRASGARD ® KFF ⁄...
  • Page 4 ® HYGRASGARD KFF ⁄ KFTF (± 3 %) ® HYGRASGARD KFF – Feuchtefühler (± 3 %), Standard HYGRASGARD ® KFTF – Feuchte- und Temperaturfühler (± 3 %), Standard Typ ⁄ WG01 Messbereich ⁄ Anzeige Ausgang Display Art.-Nr. Feuchte Temperatur Feuchte Temperatur KFF - I (aktiv)
  • Page 5 ® HYGRASGARD KFF - 20 ⁄ KFTF - 20 (± 2 %) ® HYGRASGARD KFF - 20 – Feuchtefühler (± 2 %), Premium HYGRASGARD ® KFTF - 20 – Feuchte- und Temperaturfühler (± 2 %), Premium Typ ⁄ WG02 Messbereich ⁄ Anzeige Ausgang Display Art.-Nr.
  • Page 6 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Schaltbild KFTF - xx - U Schaltbild** KFTF - xx - I mit ⁄ ohne Display mit ⁄ ohne Display (Tyr1) (Tyr1) passiver Stecker passiver...
  • Page 7 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) KFTF - 20 - U KFTF - 20 - I Schaltbild Schaltbild** mit Display mit Display (Tyr2) (Tyr2) 1 2 3 4 5 6 °C r.H.
  • Page 8 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) VERSORGUNGSSPANNUNG: Schaltbild Einzelbetrieb Als Verpolungsschutz der Betriebsspannung ist bei dieser Gerätevariante eine Einweggleichrichtung bzw. Verpolungschutzdiode integriert. Diese interne Einweggleichrichtung erlaubt auch den Betrieb mit AC-Versorgungs- spannung bei 0 - 10 V Geräten.
  • Page 9: Wichtige Hinweise

    Wichtige Hinweise – Dieses Gerät darf nur in schadstofffreier, nicht kondensierender Luft, ohne Über- oder Unterdruck am Sensorelement eingesetzt werden. – Bei Aussen- und Kanalfühlern schützt der Sinterfilter des Sensorelementes den Feuchtesensor vor eventuellen Staub belastungen. Dieser Filter sollte bei Verunreinigung ⁄ Verschmutzung regelmäßig gewartet werden. –...
  • Page 10: Technical Data

    ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Rev. 2016 - V23 GB Quality product for HVAC sector, accuracy ± 2 % or ± 3 % Calibratable duct humidity ⁄ temperature sensors HYGRASGARD ®...
  • Page 11: Accessories

    ® HYGRASGARD KFF ⁄ KFTF (± 3 %) ® HYGRASGARD KFF – Humidity sensors (± 3 %), Standard HYGRASGARD ® KFTF – Humidity and temperature sensors (± 3 %), Standard Type ⁄ WG01 Measuring Range ⁄ Readout Output Display Item No. Humidity Temperature Humidity...
  • Page 12 ® HYGRASGARD KFF - 20 ⁄ KFTF - 20 (± 2 %) ® HYGRASGARD KFF - 20 – Humidity sensors (± 2 %), Premium HYGRASGARD ® KFTF - 20 – Humidity and temperature sensors (± 2 %), Premium Type ⁄ WG02 Measuring Range ⁄...
  • Page 13 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Schematic diagram KFTF - xx - U Schematic diagram** KFTF - xx - I with / without display with / without display (Tyr1) (Tyr1) Passive...
  • Page 14 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Schematic diagram KFTF - 20 - U Schematic diagram** KFTF - 20 - I with display with display (Tyr2) (Tyr2) 1 2 3 4 5 6 1 2 3 4 5 6 °C r.H.
  • Page 15 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) SUPPLY VOLTAGE: Connecting scheme Individual operation For operating voltage reverse polarity protection, a one-way rectifier or reverse polarity protection diode is integrated in this device variant. This internal one-way rectifier also allows operating 0 - 10 V devices on AC supply voltage.
  • Page 16 General notes – This device may only be used in pollutant-free non-precipitating air without above-atmospheric or below-atmospheric pressure at the sensor element. – On outdoor and duct sensors, the sinter filter of the senor element protects the humidity sensor against potential dust exposure. In case of pollution ⁄...
  • Page 17: Caractéristiques Techniques

    ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Rev. 2016 - V23 FR Produit de qualité destiné au domaine CVC, précision ± 2 % ou ± 3 % Le capteur HYGRASGARD ®...
  • Page 18: Accessoires

    ® HYGRASGARD KFF ⁄ KFTF (± 3 %) ® HYGRASGARD KFF – Sonde d’humidité (± 3 %), Standard HYGRASGARD ® KFTF – Sonde d’humidité et de température (± 3 %), Standard Désignation ⁄ WG01 plage de mesure ⁄ affichage sortie écran référence humidité...
  • Page 19 ® HYGRASGARD KFF - 20 ⁄ KFTF - 20 (± 2 %) ® HYGRASGARD KFF - 20 – Sonde d’humidité (± 2 %), Premium HYGRASGARD ® KFTF - 20 – Sonde d’humidité et de température (± 2 %), Premium Désignation ⁄ WG02 plage de mesure ⁄...
  • Page 20 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Schéma de raccordement KFTF - xx - U Schéma de raccordement** KFTF - xx - I avec ⁄ sans écran avec ⁄ sans écran (Tyr1) (Tyr1) Passive...
  • Page 21 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Schéma de raccordement KFTF - 20 - U Schéma de raccordement** KFTF - 20 - I avec ⁄ sans écran avec ⁄ sans écran (Tyr2) (Tyr2) 1 2 3 4 5 6...
  • Page 22 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) TENSION D’ALIMENTATION : Schéma de raccordement individuel Cette variante d’appareil est dotée d’une protection contre l’inversion de polarité, c.-à.-d. elle comprend un redressement demi-onde (diode de re- dressement).
  • Page 23: Généralités

    Généralités – Cet appareil ne doit être utilisé que dans un air non pollué, sans risque de condensation, sans risque de surpression ou dépression sur l’élément sensible. – Dans le cas des sondes extérieures et des sondes pour montage en gaine, le filtre fritté de l’élément sensible protège la sonde d’humidité contre la pénétration des particules de poussières.
  • Page 24: Технические Данные

    ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Rev. 2016 - V23 RU Высококачественный датчик для систем отопления, вентиляции и кондиционирования воздуха, точность ± 2 % или ± 3 % ®...
  • Page 25 ® HYGRASGARD KFF ⁄ KFTF (± 3 %) ® HYGRASGARD KFF – Датчик влажности (± 3 %), Standard HYGRASGARD ® KFTF – Датчик влажности и температуры (± 3 %), Standard Тип ⁄ WG01 Диапазон изм. ⁄ индикация Выход Дисплей Арт. № влажность...
  • Page 26 ® HYGRASGARD KFF - 20 ⁄ KFTF - 20 (± 2 %) ® HYGRASGARD KFF - 20 – Датчик влажности (± 2 %), Premium HYGRASGARD ® KFTF - 20 – Датчик влажности и температуры (± 2 %), Premium Тип ⁄ WG02 Диапазон...
  • Page 27 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Схема подключения KFTF - xx - U Схема подключения** KFTF - xx - I с дисплеем ⁄ без дисплея с дисплеем ⁄ без дисплея (Tyr1) (Tyr1) Passive...
  • Page 28 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) Схема подключения KFTF - 20 - U Схема подключения** KFTF - 20 - I с дисплеем с дисплеем (Tyr2) (Tyr2) 1 2 3 4 5 6 1 2 3 4 5 6 °C r.H.
  • Page 29 ® HYGRASGARD KFF ⁄ KFTF (± 3 %), KFF - 20 ⁄ KFTF - 20 (± 2 %) НАПРЯЖЕНИЕ ПИТАНИЯ: Схема соединения Одиночное подключение В качестве защиты от неправильного подключения рабочего напряжения в данный вариант прибора интегрирован однополупериодный выпрямитель или диод защиты от напряжения обратной полярности. В случае приборов, рассчитанных...
  • Page 30 Указания к продуктам – Данный прибор допускается применять только в воздухе без конденсата и вредных веществ, при отсутствии пониженного или повышенного давления вблизи чувствительного элемента. – В случае датчиков для наружной и канальной установки защита чувствительного элемента датчика влажности от возможного скопления пыли обеспечива- ется...
  • Page 31 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 32 D G F r KFF - 20 HYGRASGARD ®  KFTF - 20 HYGRASGARD ®  Maßzeichnung KFF - 20 ⁄ KFTF - 20 (± 2 % ) Dimensional drawing mit Display Plan coté with display Габаритный чертеж avec écran с дисплеем (Tyr 2) M16x1.5 ø32.3...

Ce manuel est également adapté pour:

Hygrasgard kftf sérieHygrasgard kff-20Hygrasgard kftf-20

Table des Matières