English
IMPORTANT SAFETY INSTRUCTIONS
FOR BATTERY CHARGER
1.
This manual contains important safety and operating instructions for battery charger
Model UC12SD, UC14YF2, UC14YFA and UC24YFA.
2.
Before using battery charger, read all instructions and cautionary markings on (1)
battery charger, (2) battery, and (3) product using battery.
3.
<UC12SD>
To reduce risk of injury, charge HITACHI rechargeable battery type EB1212S. Other type
of batteries may burst causing personal injury an damage.
<UC14YF2, UC14YFA>
To reduce risk of injury, charge HITACHI rechargeable battery types EB7 series, EB9
series, EB12 series, EB14 series. Other type of batteries may burst causing personal
injury and damage.
<UC24YFA>
To reduce risk of injury, charge HITACHI rechargeable battery types EB7 series, EB9
series, EB12 series, EB14 series, EB18 series, and EB24B. Other type of batteries may
burst causing personal injury and damage.
4.
Do not expose battery charger to rain or snow.
5.
Use of an attachment not recommended or sold by the battery charger manufacturer
may result in a risk of fire, electric shock, or injury to persons.
6.
To reduce risk of damage to electric plug and cord, pull by plug when disconnecting
battery charger.
7.
Make sure cord is located so that it will not be stepped on, tripped over, or otherwise
subjected to damage or stress.
8.
An extension cord should not be used unless absolutely necessary. Use of improper
extension cord could result in a risk of fire and electric shock.
If extension cord must be used make sure:
a.
That blades of extension cord are the same number, size, and shape as those of plug
on battery charger:
b. That extension cord is properly wired and in good electrical condition; and
c.
That wire size is large enough for AC ampere rating of battery charger as specified
in Table 1.
AC Input Rating Amperes*
Equal to or
greater than
0
2
3
8
RECOMMENDED MINIMUM AWG SIZE FOR
EXTENSION CORDS FOR BATTERY CHARGERS
but less
than
2
3
4
Table 1
AWG Size of Cord
Length of Cord, Feet (Meter)
25 (7.5)
50 (15)
18
18
18
18
18
18
100 (30) 150 (45)
18
16
16
14
16
14