The S1 allows the temperature
and the slope angle to be measured.
Measuring the slope:
The tolerance of the slope sensors at 30° (degrees)
can be up to +-5°. The determined measurement can
be kept by pressing the "OK" button (2). A new measu-
rement can be taken by pressing the "OK" button (2)
again.
DAILY FUNCTION TEST BEFORE STARTING A TOUR!
Checking the receivers:
• All participants set their S1 to 'RECEIVE'.
• A group member (preferably the group leader) sets his/her S1
to 'TRANSMIT'.
• If all group members have acoustic and optical reception then
the group members' receivers are working, as is the transmitter of
the group leader.
• The group leader now moves away from the group until no group
member is still receiving a signal.
• The group members see the increase in distance of the group
leader on their displays and can thus test the reception range
of their S1.
Checking the transmitters:
• The group leader opens his S1 (=reception position). The group
members close their S1 (transmission position) and pass the group
leader's receiver ONE BY ONE at a distance of 20 m.
At the same time, the fine search is tested approaching under 3 m !