There are several causes for this alarm:
The electrode may be covered by deposits of limescale
Too much salt
Short-circuit in the electrode connections
A fault in the electronic control box
CORRECTIVE ACTIONS
1 – Remove the electrode and inspect its state visually. If you can see a large quantity of limescale
deposits, immerse the electrode in a solution of pH corrector (negative pH) until the limescale
disappears completely. Never rub the electrode plates nor submerge the connection terminals.
Rinse the electrode and replace it in the cell.
The self-cleaning function of the electrode prevents the formation of limescale deposits in the
majority of cases. However, in regions with exceptionally hard water or "unbalanced" water
(see the Taylor Balance diagram), manual cleaning of the electrode or a treatment to balance
the water may be necessary.
2 – Contact a pool specialist who can advise you on replacement of the electrode.
3 – Contact our technical:
Have the following items at hand:
The purchase invoice
The serial number of the electronic control box and the electrode
The installation date of the unit
The name of the specialist who sold you and/or installed the equipment
The salinity, pH, chlorine concentration, water temperature and stabiliser concentration in
the pool
The volume of the pool and the daily operating time of the filter system
7. WINTERING
When the water temperature drops below 15° C, the unit must be turned off to avoid
irreversible damage to the electrode. In these circumstances, substitute the treatment with a classical
chemical treatment.
8. GUARANTEE
We have used the greatest care and our technical experience in the manufacture of this equipment,
which has been subjected to quality-control procedures. If, despite the attention and knowledge
applied to its manufacture, you should have to use the guarantee, you should remember that it only
covers free replacement of defective parts supplied by us.
Guarantee cover
The guarantee applies to all parts except those that require replacement every year.
The equipment is guaranteed against any manufacturing defect, strictly in the context of normal use
in private swimming pools. Its use in public pools annuls all guarantees.