ñ
LIFTINSTITUUT
PR00ufls
flvA
[
û01
Also is it possible to open the lock by means of
a triangular key
according Fig.
13
of
EN81-20. The used locking contact is the following:
Manufacturer
Prudhomme
S.a.
Ue/1"
250 VAC / 2,0
A
AC
3.
Examinations and tests
The examination covered a check whether compliance with the Lift Directive
201413318U is met, based on
the harmonized product standards EN 81-20:2014 and
EN 81-50:2014.
The examination included:
Examination of the technical file (See annex
2):
Examination of the representative model in order to establish conformity with
the technicalfile.
lnspections and tests to check compliance with the requirements.
The tests which are performed are as stated in clause 5.2 of EN 81-50.
The mechanical and electrical tests are performed on the LRC-E-O15 locking device.
This is a locking device with the checking pin integrated
in
the locking pin and has
a
perpendicular unlocking arm.
Additionally, only mechanical tests are performed on the LRC-E-030 locking device.
This
is
a locking device with the checking pin
in
the back side of the lock housing
and
has a lateral unlocking arm.
For all different subtypes the locking contact and its operation by internal mechanism
is identical.
3.1 Mechanical tests
Endurance test
According clause 5.2.2.2.2 of EN 81-50 an endurance test must be made.
For
this
test a specials testing apparatus was designed. With 60.0 rpm the actuator rod was
driven.
A
mechanical counter was installed to keep track of the number of complete
cycles.
Test details for
LRC-E-015
Start date /
time
January
261h,2017
I
14:15
End date /
time
February 07th,2017
I
15:00
Number of
cycles
>1.000.000
Test result: OK
Test details for
LRC-E-030
Start date /
time
January 25th,2017 / 09:00
End date /
time
February 71h,2017
I
05:15
@
L|FT|NSTITUUT
B.V.
NLl6-400-1002-125-07
rev.
-
datei'14-02-2017
Page 2
of
11
No part of this
work may
be reproduced
¡n
any
form
by pr¡nt,
photo-print,
m¡crof¡lm or any other means without
written
permission
from
L¡ftinstituut
B.V. '*'.'....'*.-
,'"
LIFT]NSTITUUT
B V
_
SAFETY
AND
QUALITY
MANAGEMENT
I
Buikstotermeerplein
381
|
P.0. Box
36027
|
Tel".
+31
20
-
435
06
06 |
www.l.iftìnstituut.nl
i
VAT
number:
I
I
¡¡L-rOz¡XE
Amsterdam
I
NL-1020M4
Amsterdam
I
Fax+3120-4350626
I
contact@liftinstituut.nl
I
N1810399441801
I
Registered by
the
Dutch Chamber
of
Commerce nr. 34157363. Generat
terns
of
suppty
of Liftinstituut
B.V.
are
registered at
the
Duth
Chamber
of
Commerce.
under
number 34157363.