Télécharger Imprimer la page

Miele UG 6008 Notice De Montage page 8

Socle

Publicité

Produktgruppen 512, 522, 592
8 von 28
Abbreviation
UM
A-A
B
C
Table 1: Abbreviation legend
Close the gas stopcock if applicable.
Disconnect the machine from the gas (if applicable) and electric mains and ensure utilities cannot be switched on again in error.
Mark hole positions in accordance with the drawing, Fig. 2.
Note
The gap between the machine and a wall at the side must be at least 10 mm.
Drill 4 holes 12 mm Ø approx. 65 mm deep in the floor as shown, Fig. 3.
Insert 4 S12 Rawl plugs flush in the holes, Fig. 4, Pos. 1.
Fit spacer plates, Fig. 4, Pos. 2, as appropriate and use the spirit level to level the plinth.
Secure the plinth with four 8 x 65 hexagon head wood screws, Fig. 4, Pos. 3, 8.4 washers, Fig. 4, Pos. 4, and 38 mm Ø washers,
Fig. 4, Pos. 5, to the floor.
Place the machine on the plinth.
Danger!
Risk of injury, particularly to the back. The relation of the weight of the machine to the physical strength of the technician must be taken
into account. For machine weight details, see the appropriate operating instructions.
Risk of crushing. When carrying out work, ensure that parts of the body, especially the hands and feet are not positioned under or
between machines.
Fit 4 clamps, Fig. 6, Pos. 1, over the machine feet.
Insert four M6 bolts, Fig. 6, Pos. 2, with B6.4 galvanised washers, Fig. 6, Pos. 3, from above through the existing holes.
Secure the 4 clamps from below with 38 mm Ø washers, Fig. 6, Pos. 4, B6.4 galvanised washers, Fig. 6, Pos. 3, and M6 nuts,
Fig. 6, Pos. 5, tightened from below.
Counter the clamp nuts with additional M6 nuts, Fig. 6, Pos. 6, tightened from below.
Danger!
Risk of toppling and falling! It is absolutely essential to secure the plinth to the floor and the machine to the plinth.
Note
For details of the drain connection in the floor or wall, see the PW 6080 installation plan.
Note
Fixing materials for a floating screed floor are to be provided on site.
UG 6008 plinth
Fit the 2 side panels with M4 x 12.4 raised-head screws (Torx 20), Fig. 7.
Fit the 2 side panels with M4 x 12.4 raised-head screws (Torx 20), Fig. 7.
Carry out appropriate safety checks.
Reconnect the machine to the gas (if applicable) and electric mains.
Carry out a functional test either with the service programme or a wash programme. Check the drain connection from the machine to
the on-site drain in the floor or wall for leaks.
en
22.02.2012
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Explanation
Miele plinth
Section plane
Floor fastening
Detail
Umbau- und Montageanweisung
M.-Nr. 07707491