Télécharger Imprimer la page

Miele UG 6008 Notice De Montage page 7

Socle

Publicité

Produktgruppen 512, 522, 592
7 von 28
Danger!
Even with the machine switched off, mains voltage may be applied to some components.
Before any service work is commenced, the machine must be disconnected from the mains. Suitable measurements must be made to
ensure that this is the case. The machine must be disconnected from the gas mains.
A general visual check should always be carried out.
Incorrect conversion or service work could lead to a risk of fire or gas explosion.
Danger!
Risk of injury during fitting
Risk of electric shock. Before any service work is commenced, the machine must be disconnected from the mains.
Fitting can only be carried out with the washing machine or tumble dryer not installed. For deinstallation, see the appropriate
operating instructions.
Risk of crushing. Wear slip-proof working gloves and safety shoes.
Risk of crushing. When carrying out work, ensure that parts of the body, especially the hands and feet are not positioned under or
between machines.
Risk of accident. Ensure that children or pets cannot access the work area while fitting work is being carried out.
Risk of injury, particularly to the back. The relation of the weight of the machine to the physical strength of the technician must be
taken into account. For machine weight details, see the appropriate operating instructions.
Risk of toppling over. Risk of injury due to incorrect fitting.
Always bolt the machine to the plinth.
With a single machine installation, secure the plinth to the floor with the fastening accessory. This is supplied with the kit.
With floor fastening, secure all four plinth feet.
The plinth must not be used with a washer-dryer stack.
Note
The plinth may only be used with the following Miele models:
PW 6080, PW 5082, PT 7186, PT 5186
Note
Tools required:
Spirit level for plinth levelling
Open spanner 10 mm for M6 nut
Torx screwdriver, T 20
Note
The fitting kit - Plinth UO 6008 Mat. no. 07689330, or fitting kit - Plinth UG 6008, Mat. no. 07129240, contains the following:
1 plinth UO 6008 with fitting kit - Plinth UO 6008, Mat. no. 07689330
1 plinth UG 6008, 1 x Front panel, 2 x Side panel, 12 x Raised-head screw M4 x 12.4, with fitting kit - Plinth UG 6008,
Mat. no. 07129240
1 floor fastening accessory pack containing the following: 4 x Clamp, 8 x Galvanised washer B6.4, 4 x Bolt M6 x 30, 8 x Nut M6,
4 x Rawl plug S12, 4 x Washer 8.4, 4 x Hexagon head wood screw 8 x 65, 20 x Spacer plate, 8 x Washer 38 mm Ø
1 information sheet with these instructions and commissioning card. These fitting instructions are called Fitting instructions -
Plinth UO 6008 / UG 6008 .
List of illustrations:
Fig. 1: Plinth height
Fig. 2: Floor fastening drilling plan
Fig. 3: Floor fastening hole dimensions
Fig. 4: Floor fastening
Fig. 5: Plinth UO 6008
Fig. 6: Clamp fitting
Fig. 7: Plinth UG 6008
22.02.2012
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
M.-Nr. 07707491