TROUBLESHOOTING
Leaks between head and cartridge
1.
Turn off the water supply to the filter and dispense water
from drinking water faucet until water flow stops.
2.
Remove cartridge and inspect o-rings to make sure they are
in place and clean.
3.
Install cartridge and turn on water supply. If it still leaks,
contact OMNIFILTER Customer Service at 800.937.6664
Monday-Friday 7:30 AM-5 PM CST. Turn off icemaker if
filtered water goes to icemaker.
Leaks from fittings
1.
Turn off water supply to the filter and turn on drinking water
faucet to release pressure in system. Press in gray collar
surrounding tubing while pulling the tubing with your other
hand. Check if tubing is cut squarely and not scratched, cut
tubing if necessary to get square smooth end. If the tubing
is smooth and square, reconnect tubing by pushing into
fitting 5/8-inch to hard stop. Open the water supply valve,
then close faucet and check for leaks. If the leaks persist, or
if there are other leaks on the unit, turn off the water supply
then call OMNIFILTER Customer Service at 800.937.6664.
Leaks on supply adapter connection
2.
Turn off water supply valve and turn on drinking water faucet
to release pressure in system. Loosen leaking threaded fitting
on supply adapter or pull out leaking tubing from fitting
per NOTE in Step 5: Connecting the Faucet. Inspect to see
if plastic tubing is scratched or supply adapter was properly
attached. If tubing is scratched, cut off 1/2-inch to 5/8-
inch and reinstall per Step 6: Connecting the Water Supply
Adapter, page 4. Reconnect tubing or tighten compression
nut with fingers, then tighten nut snugly 1/2-turn with
wrench. Turn on water supply valve and check for leaks.
Leaks on faucet/tubing connection
3.
Turn off water supply valve and turn on drinking water
faucet to release pressure. Press in gray collar surrounding
tubing while pulling the tubing with your other hand. Check
if tubing is cut squarely and not scratched, cut tubing if
necessary to get square smooth end. If the tubing is smooth
and square, reconnect tubing by pushing into fitting 5/8-inch
to hard stop. Turn on water supply valve, then close faucet
and check for leaks.
NOTE: If leaks persist, or if there are other leaks on system,
turn off water supply and call OMNIFILTER Customer Service
at 800.937.6664.
The SFM2 with the 800R replacement cartridge is Tested and Certified by NSF
International to NSF/ANSI Standard 42 for the reduction of Chlorine Taste
and Odor.
The CBF2 with the 1100R replacement cartridge is Tested and Certified by NSF
International to NSF/ANSI Standard 42 for the reduction of Chlorine Taste and
Odor and Particulate Class I and Standard 53 for the reduction of Cysts, Lead,
Atrazine and Turbidity.
• 6 •

PERFORMANCE DATA

Important Notice: Read this performance data and compare
the capabilities of this system with your actual water treatment
needs. It is recommended that, before installing a water
treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 and 53
for reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 42
and 53.
Model SFM3 with 800R
Influent Challenge
Substance
Concentration
Standard 42
Chlorine
2.0 mg/L ± 10%
Flow rate = 0.75 gpm (2.8 Lpm) Capacity = 2,500 gallons (9460 L) or 12 months
Testing was performed under standard laboratory conditions, actual performance may vary.
Model CBF2 with 1100R
Influent Challenge
Substance
Concentration
Product Water
Standard 42
Chlorine
2.0 mg/L ± 10%
at least 10,000
Particulates
(0.5–<1m) Class I
particles/mL
Standard 53
Minimum
Cysts
50,000/L
Turbidity
11 mg/L±1 NTU
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
0.002 mg/L
Lindane
0.0002 mg/L
± 10%
0.009 mg/L
Atrazine
± 10%
Flow rate = 0.5 gpm (1.89 Lpm) Capacity = 500 gallons (1,892 L) or 6 months
Testing was performed under standard laboratory conditions, actual performance may vary.
Test Conditions
Flow Rate
= as noted for filter system
Inlet Pressure
= 60 psi (4.1 bar)
pH
= 7.5 ± 1
Temperature
= 68°F ± 5°F (20°C ± 2.5°C)
Operating Requirements
Pressure
= 30-125 psi (2.1–8.62 bar)
Temperature
= 40°F-100°F (4.4°C–37.8°C)
Turbidity
= 5 NTU Max.
WARNING
Do not use with water that is microbiologically unsafe or unknown quality
without adequate disinfection before or after the system. Systems certified for cyst reduction may
be used on disinfected waters that may contain filterable cysts.
NOTE: The contaminants or other substances removed or reduced by this water treatment
device are not necessarily in your water. Filter must be maintained according to manufacturer's
recommendations, including replacement of filter cartridges.
Suggested Retail Price:For replacement filter cartridge pricing call OMNIFILTER Customer Service
at: 800.937.6664
Reduction
Minimum
Average
Requirements
Reduction
Reduction
≥50%
87.8%
Maximum
Reduction
Permissible
Requirements
Minimum
≥50%
≥85%
99.95%
99.99%
99.99%
0.5 NTU
99.6%
99.97%
0.010 mg/L
99.3%
0.010 mg/L
98%
97.5%
0.003 mg/L
97.7%
Average
99%
99.8
99.3%
98.6%
97.5%
97.7%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cbf2

Table des Matières