2. After around one minute the results can be seen on the test strip.
Some of the green fields change colour into pink. The water hardness is shown
by how many boxes turn pink. Example: If three are pink, then the water hard-
ness is >14 °dH.
Number of
pink boxes
0/1
2
3
4
With a water hardness above 21 °dH, we can no longer recommend the use
of an ultrasonic humidifier. We recommend that you use an evaporative
humidifier to increase the humidity in your house (e.g. an Oskar humidifier
made by Stadler Form: www.stadlerform.com/Oskar).
Note: Do not operate Eva with decalcified water out of a decalcification
system that uses the principle of an ion exchanger (salt is added to the wa-
ter). The salt contained in the water may lead to white dust accumulation
around the appliance. To minimize this risk, you can operate Eva using a mix
of distilled and tap water. The mixing ratio should be 50:50.
Attention: Please do not operate the unit using pure distilled water as the
water level indicator will not work correctly. However, Eva may be operated
from a drinking water filter system (e.g. Brita). Should you be unsure about
the quality or composition of the water in your area, contact the caretaker or
your drinking water provider.
Setting up / operation
1. Put Eva in the desired location on a flat surface. The mist reaches a
height of up to 1.4 m thanks to the high-performance humidification (out-
put level 5, warm mode on). This makes it possible to place Eva directly
on the floor. Connect the power cord (1) to a suitable socket.
2. Take the Remote Sensor
the packaging. Open the battery compartment (4) on the underside of
the Remote Sensor
batteries into the battery compartment (4), as shown on page 4, and
close the lid again. Now place the Remote Sensor
3. On the one hand, the Remote Sensor
guarantees precise humidification by its external position. On the other
hand, the Remote Sensor
the humidity sensor Remote Sensor
table or a sideboard with an optimal distance from Eva between 3 – 5 m.
The Remote Sensor
the room air can flow past the sensor (5) as freely as possible. If this is
not possible, we recommend positioning the Remote Sensor
minimum distance of 30 cm from the wall and a minimum distance of 2 m
from windows and ventilation openings.
Water
Degree of
hardness
hardness
(°dH)
Soft
From 4 °dH
Moderately
From 7 °dH
hard
Hard
From 14 °dH
Very hard
From 21 °dH
(2), the stand (3) and the two batteries out of
TM
(2) by turning the lid anticlockwise. Insert the two
TM
(2) also serves as a remote control. Position
TM
should be positioned centrally in the room so that
TM
Cartridge will last for
(with 4 liter/day)
Days
90 days
45 days
30 days
15 days
TM
(2) is a humidity sensor and
TM
(2) in the centre of the room on a
TM
Liter
approx. 360 L
approx. 180 L
approx. 120 L
approx. 60 L
(2) on the stand (3).