Checking For Correct Assembly; Emergency Manoeuvres, Maintenance And Cleaning; Troubleshooting - GIESSE RACK MAX 650 Manuel D'utilisation Et D'installation

Masquer les pouces Voir aussi pour RACK MAX 650:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 64
6. Re mount everything back onto the body of the actuator.
7. Screw in the four screws on the front head and check the settings for the new
track run.

11. Checking for correct assembly

• Check that the frame has closed completely, even at the corners, and check there
are no obstacles caused by assembly in the wrong position.
• Make sure the actuator is aligned with the axis of the window at 90° to the window
itself, otherwise the rack will exert incorrect pressure on the rod and consume more
voltage.
• Check the lead is not too tight, as this could damage the actuator during rotation,
opening and closing of the window.
• Check all screws and nuts have been properly tightened.

12. Emergency manoeuvres, maintenance and cleaning

Should the window have to be opened manually in the event of no electricity,
mechanical failure, or for normal maintenance or cleaning of the external surface of the
window frame, the following instructions should be followed:
1. Unscrew the nut from the pin screw fixing the eyebolt head to the front shaft.
2. Hold the window with one hand and use the other hand to remove the pin screw
(this operation should be performed with the window open at least 10 cm to make
it easier to remove the screw).
3. Manually open the window.
A
TTENTION
FALLING OUT AS IT IS NO LONGER HELD IN PLACE BY THE RACK
4. After maintenance and/or cleaning operations are complete, repeat points 1 and
2 in reverse order.
In the event in which the cable of feeding it is damaged, to make to replace it from the
constructor or a qualified technician.

13. Troubleshooting

Please consult the following table for any eventual problems with function during
installation or normal use:
Problem
• Gear motor does not
work.
:
RISK OF THE WINDOW FALLING OUT
Possible cause
• No electricity at source.
• Lead not connected, or
one of the wires has come
loose.
;
• Check trip switch and
safety switch.
• Check all electrical
connections on gear motor.
38
THE SASH IS IN DANGER OF
.
Solution

Publicité

Table des Matières
loading

Table des Matières