G. Insert the dove-tailed section of the actuator into the clamp screws. Make sure the
shaped part of the base fits neatly into the slot to ensure the actuator runs smoothly
along its axis.
H. Now position the actuator so the eyebolt head is inserted into the front bracket
support. Insert the M6x25 screw into the bracket and into the eyebolt and tighten the
self-locking bolt with two 10 spanners.
I. Manually move the actuator along its axis to close the frame and make it weather
tight. Tighten the clamp screws previously only placed and set the actuator in line
with the frame. Suggested tightening torque is 5÷7 Nm.
J. Plug the actuator in and carry out a test to check opening and closure of the frame.
Make sure the frame closes fully and is weather tight.
K. The limit switch for the actuator is automatic on reentry. The equipment will exert a
pressure to guarantee even the largest of frames is completely weather tight.
8.5. Assembly of more than one actuator with connection bar
RACK MAX 650 actuators can be used in tandem or series by means of a mechanical
connection bar. Movement is thus transmitted mechanically and uniformly and at the
same speed.
It is possible to install two or more actuators (M) with one or more drive units (R) to the
window in compliance with the needs required . The following diagram indicates position
and distance between centres to be used during mounting.