Installation Tips
5.
When connecting to an HA system
(wired remote controller, central remote controller etc.)
• Removal methods for metal plate
electrical wiring box covers
1) Remove the upper front panel and front
grille. (Refer to the removal method on
page 11.)
2) Remove the electrical wiring box. (1 screw)
3) Remove the 4 tabs and dismount the metal
plate electrical wiring box cover (A).
4) Pull down the hook on the metal plate
electrical wiring box cover (B), and remove
a single tab.
5) Remove the 2 tabs on the top part and
dismount the metal plate electrical wiring
box cover (B).
• Attachment methods of connection cord
1) Remove the factory-mounted connector from S21.
2) Tie the harnesses in a bundle as shown in the figure so that the removed
connector does not interfere with the printed circuit board.
3) Attach the connection cord to
the S21 connector and pull
the harness out through the
notched part in the figure.
• Attachment methods for
metal plate electrical wiring box covers
1) Hook the top part of the metal plate electrical wiring box
cover (B) on the 2 tabs.
2) Press in the hook on the bottom to catch a single tab, and
mount the metal plate electrical wiring box cover (B).
3) Insert the connector into the hole, and hook and mount the
metal plate electrical wiring box cover (A) onto the 4 tabs.
4) Install the electrical wiring box. (1 screw)
5) Install the upper front panel and front grille.
(Refer to the installation method on page 11.)
13
Metal plate electrical
wiring box cover (A)
Screw
Screw
Metal plate electrical
wiring box cover (B)
From back side
Single tab
Pull down
Factory-mounted
connector
HA connector (S21)
Metal plate electrical
wiring box cover (B)
Metal plate
electrical wiring
box cover (A)
■
English